9.4.1.
T
ABLE OF CONFIGURATION PARAMETERS
To correctly display the parameter values, you need to load them from the low kit, using
the "Read from low kit" function.
After any changes to the parameter values, you need to save them in the low kit using
the "Write to low kit" function.
Display
Unit of
parameter
measure
P01
Kmh*10
(Kmh*100)/sec Default acceleration and deceleration
P02
P03
%*2
Numerical
P04
Constant
Numerical
P05
Constant
Numerical
P06
Constant
P07
on/off
P08
10msec
P09
1msec
P10
on/off
P11
Numerical
P12
constant*100
P13
on/off
I.e.
 P01 = kmh = 8 / 10 is the 0.8kmh of start, (as if the unit was hundreds of meters times).
 P02 = 100 means the acceleration expressed in kmh/sec is 100 / 100 = 1 where the 100 is the
value of the numerator and the denominator is the default 100 of formula. (cents of kmh/sec)
 P03moltiplication by two is to take steps to 0.5%, this basically 2 means 1%.
 Numerical Constant: P04-P05-P06 is a pure number, multiplicative constant used by the
firmware.
 P07, P10, P13 is a Boolean flag, yes or not.
 P08 is expressed in tens of msec: if P08 = 100 will be a second.
 P12 = 211 means that the transmission ratios is 2.11.
Pagina 9.22
Default linear speed
default slope set point
PID proportional gain
PID Integral gain
S Ramp Type
Flag DC motor encoder signal alarm action
Watchdog serial communication
DC motor encoder error timeout 1 cnt = 100 msec
Flag signal receiving Sw Emergency and not
receiving Emergency Hw
mm
roll diameter
roller diameter
Flag posting warning signal AC motor encoder
JOG NOW Excite +: Service & maintenance manual - rev. 5.1
(VISIO):
Description
VISIO
Default
values
8
100
0
7
150
0
0
0
15
0
74
211
0