Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Check the correct display SW version, according to the "EXCITE SW SMART TABLE" you
can find in TG Direct section.
(2)
Check if the receiver has been correctly mounted on the machine, as detail at paragraph: 7.6.2.
"HR Receiver (Chest Belt)".
(3)
Place the tester probes across pins 1 and 2 on HD4 connector of receiver. The measured value
should be +5Vdc.
(4)
As at step (3) but on pin 1 and 8 on CN9 connector of CU141 cable (ARM Board).
If you replace CPU/ARM Board, check that its SW version is updated, otherwise install
the last version.