Com.fault X; View Errors; Standard Settings - Technogym Jog Now Excite+ 700 Service Maintenance Manual

Jog now excite+ series; rev. 5.1
Hide thumbs Also See for Jog Now Excite+ 700:
Table of Contents

Advertisement

9.2.4.3.
COM.Fault
This is a counter that displays the number of errors in serial communication between the upper and
the lower kit. This counter increase each time a communication fault is detected. Scroll using the +/-
keys until the display shows:
To reset it press ENTER, the LED display shows:
Press ENTER to reset and return to the upper menu level by pressing CLEAR for a few seconds.
9.2.4.4.

View Errors

For every error generated by the machine, the error history log records the information in the table
below:
• Error number;
• Error code;
• Tension at the error moment;
• Current when the error occurred
• Speed at the error moment Km/h.
The correspondence between error codes and descriptions is given at paragraph: 6.10. "driver
errors" of this manual.
Use the + effort level key to advance to the next error, otherwise the message with the details of the
current error will continue to reappear.
9.2.5.
S
TANDARD SETTINGS
This function simultaneously resets the User menu, low kit, UpDown table parameters to their
default values and the operating data of the machine. To access this menu, when the LED display
shows:
Press ENTER, the following message appears:
Press ENTER again to reset all parameters to their default values, or return to the upper menu level
by pressing CLEAR for a few seconds.
This function does not alter the language and the TV standard setting.
Pagina 9.16
JOG NOW Excite +: Service & maintenance manual - rev. 5.1

COM.FAULT X

RESET COM.FAULT?
STANDARD SETTING
CONFIRM ?