Monitor Function Parameters - Technogym Forma Service Maintenance Manual

Table of Contents

Advertisement

9.5.1.
M
ONITOR FUNCTION PARAMETERS
Parameter Description
d01
d02
d04
d05
d06
d07
d08
d09
9.5.2.
M
ODIFIED PARAMETER SETTINGS
The following table shows the parameters which must be configured with a different value from the
inverter defaults:
Parameter Description
A04
Maximum frequency setting
A61
Maximum frequency limit
A62
Minimum frequency limit
A81
Selection of AVR function
A82
Selection of voltage of AVR function for the motor
b12
Level of electronic thermal setting
b22
Level of overload restriction setting
b83
Carrier frequency setting (KHz)
b90
Dynamic braking usage ratio
C03
Function of terminal 3 setting
C13
Condition of terminal 3 setting
C41
Level of overload signal setting
C81
Analog meter adjustment O
C82
Analog meter adjustment OI
H02
Motor data selection
H03
Motor capacity setting
H05
Motor constant K
H20
Motor constant R1 setting
H21
Motor constant R2 setting
H22
Motor constant L setting
H23
Motor constant Io setting
H24
Motor constant J setting
H30
Motor constant R1 (Autotuning data)
H31
Motor constant R2 (Autotuning data)
H32
Motor constant L (Autotuning data)
H33
Motor constant Io (Autotuning data)
H34
Motor constant J (Autotuning data)
Page 9.6
Motor output frequency
Motor current draw
Direction of movement
Status monitor of intelligent terminal input signals
Status monitor of intelligent terminal output signals
"Converted" motor output frequency
Monitor of last alarm condition
List of the last error conditions
setting
p
FORMA: Service & Maintenance manual - rev. 3.0
Forma 3
12.00
2.984
1.598
18.16
2.984
1.598
18.16
Value
Forma 2
80
100
80
80
4.6
4.6
00
00
240
240
6.00
6.00
12.00
16.0
16.0
20
20
12
12
01
01
5.00
5.00
99
99
75
75
01
01
1.1
1.1
99
99
2.984
1.598
18.16
2.61
2.61
20
20
2.984
1.598
18.16
2.31
2.31
20
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents