JOG NOW Excite +: Service & maintenance manual - rev. 5.1
9.2.1.4.
Table of configuration parameters (LED):
Display
Unit of
parameter
measure
P01
Kmh*10
P02
(Kmh*100)/sec Default acceleration and deceleration
P03
%*2
Numerical
P04
Constant
Numerical
P05
Constant
Numerical
P06
constant
P07
on/off
P08
10msec
P09
1msec
P10
on/off
P11
Numerical
P12
constant*100
P13
on/off
I.e.
P01 = kmh = 8 / 10 is the 0.8kmh of start, (as if the unit was hundreds of meters times).
P02 = 100 means the acceleration expressed in kmh/sec is 100 / 100 = 1 where the 100 is the
value of the numerator and the denominator is the default 100 of formula. (cents of kmh/sec)
P03moltiplication by two is to take steps of 0.5%, this basically 2 means 1%.
Numerical Constant: P04-P05-P06 is a pure numbers, multiplicative constants used by the
firmware.
P07, P10, P13 is a Boolean flag, yes or not.
P08 is expressed in tens of msec: if P08 = 100 will be a second.
P12 = 211 means that the transmission ratios is 2.11.
Pagina 9.11
Default linear speed
default slope set point
PID proportional gain
PID Integral gain
S Ramp Type
Flag DC motor encoder signal alarm action
Watchdog serial communication
DC motor encoder error timeout 1 cnt = 100 msec
Flag signal receiving Sw Emergency and not
receiving Emergency Hw
mm
roll diameter
roller diameter
Flag posting warning signal AC motor encoder
Description
LED
Default
values
8
100
0
7
150
0
0
0
15
0
74
211
0