d01
d02
d04
d05
d06
d07
d08
d09
9.5.2.
M
ODIFIED PARAMETER SETTINGS
The following table shows the parameters which must be configured with a different value from the
inverter defaults:
Parameter Description
A03
A04
A44
A81
A82
b01
b02
b03
b12
b13
b22
b83
b90
C03
C13
F-02
F-03
H01
H02
H03
H04
H05
H06
H30
H31
H32
H33
H34
Page 9.6
Motor output frequency
Motor current draw
Direction of movement
Status monitor of intelligent terminal input signals
Status monitor of intelligent terminal output signals
"Converted" motor output frequency
Monitor of last alarm condition
List of the last error conditions
Base frequency setting
Maximum frequency setting
V/F Characteristic curve selection
Selection of AVR function
Selection of voltage of AVR function for the motor
Selection of restart mode
Allowable under voltage power failure time
Time delay enforced before motor restarted
Level of electronic thermal setting
Electronic thermal characteristic
Level of overload restriction setting
Carrier frequency setting (KHz)
Dynamic braking usage ratio
Function of terminal 3 setting
Condition of terminal 3 setting
Acceleration
Deceleration
Auto-tuning setting
Motor data selection
Motor capacity setting
Motor poles setting
Motor constant K
setting
p
Motor stabilization constant
Motor constant R1 (Autotuning data)
Motor constant R2 (Autotuning data)
Motor constant L (Autotuning data)
Motor constant Io (Autotuning data)
Motor constant J (Autotuning data)
SPAZIO FORMA: Service & Maintenance manual - rev. 1.0
Value
50
80
02
01
240
02
25.0
0.3
8.00
01
12.00
16.0
20
12
01
10.0
10.0
00
01
1.5
4
20
100
1.124
1.500
8.99
3.95
20