Monitor Plug For C-Safe Port; Upgrade Visioweb; Visio Vs Visioweb; Visioweb Upgrade Kit - Technogym RUN PERSONAL Service Maintenance Manual

Hide thumbs Also See for RUN PERSONAL:
Table of Contents

Advertisement

4.2. MONITOR PLUG FOR C-SAFE PORT

When the plug code 0WC00639AA is fitted into any one of the C-Safe ports on the machine, the
corresponding LED should illuminate to indicate the presence of the 5 Vdc supply on the port.
During the C-Safe port test function, the plug connects the transmit channel directly to the receive
channel, thereby producing a positive test outcome if the port is functioning correctly.

4.3. UPGRADE VISIOWEB

4.3.1.
VISIO
VS
The two product versions differ mainly for two reasons briefly detailed below. The first it's about its
functionality while the second it's about a technical characteristic.
1. On VISIOWEB it is possible to use internet. On machines with VISIOWEB display it is
possible for the user browsing and use internet services during the training session;
2. VISIOWEB has been developed on Linux instead of Windows CE used for VISIO. This
difference can not be noticed by the final user because both the product versions have the
same graphic interface and just few steps of the network configuration are different.
4.3.2.
VISIOWEB
It is possible to upgrade an equipment from VISIO to VISIOWEB through a specific SW upgrade
procedure, using the proper USB recovery stick and a correct configuration for internet service (if
the infrastructure has been properly arranged).
The Baan code to be used for this upgrade ATS600.
CAUTION: this procedure must mandatory be done by a TECHNOGYM qualified
technician.
Page 4.2
VISIOWEB
UPGRADE KIT
RUN PERSONAL: Service & maintenance manual - rev. 3.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents