JOG NOW Excite +: Service & maintenance manual - rev. 5.1

6.1.2.1. Man. Keyboard Test

The manual keyboard test checks the functioning of all the keys on the keyboard. After accessing
the test by pressing ENTER, the message "Press all buttons (beep=OK)" appears on the display.
Pressing each key will produce an audible signal; if a key does not produce the beep it means it is
not working properly.

6.1.2.2. Man. Inverter Test

The manual inverter test displays the values output by the inverter drive during movements of the
tread belt motor. The values displayed are:
• Tread belt motor drive frequency (x100);
• Current (x10);
• Voltage.
During the test it is possible to change the speed using the + and – speed keys, to see the change in
the values of frequency, current and voltage.

6.1.2.3. Man. UpDown Test

The manual UpDown test displays the values output by the elevation motor drive during machine
incline movements. The values displayed are:
• Machine incline position;
• Number of pulses generated by the elevation motor encoder;
• State of limit switch: if it is pressed, "MIN" is shown, nothing in the other condition.
During the test it is possible to vary the incline using the ↑ and ↓ elevation keys, to check that the
values vary accordingly