Line Cards - Dell PowerConnect J-EX4200-24T Software Manual

J series; j-ex series
Table of Contents

Advertisement

Line Cards

Cooling System
installed in the front of the chassis in the slots labeled RE0 and RE1. A base configuration
(AC version) J-EX8216 switch has one RE module. A redundant configuration J-EX8216
switch has a second RE module for redundancy. See Routing Engine (RE) Module in a
J-EX8216 Switch and J-EX8216 Switch Configurations.
The Switch Fabric (SF) modules provide the switching functionality to a J-EX8216 switch.
The SF modules are hot-insertable and hot-removable field-replaceable units (FRUs).
All eight SF modules are installed in the rear of the chassis in the slots labeled SF7 through
SF0. In a J-EX8216 switch, all eight SF modules are active and must be installed in the
switch for normal operation. If a single SF module fails, the input/output traffic for that
module is load-balanced among the remaining SF modules, providing graceful degradation
in midplane performance. The impact of an SF module failure on the performance of a
J-EX8216 switch varies based on the type of line cards installed in the switch and the
traffic mix flowing through them. In a J-EX8216 switch configuration that is fully loaded
with 8-port 10-Gigabit Ethernet SFP+ line cards, if one SF module fails, the remaining
seven SF modules still have sufficient switching capacity to maintain continuous switch
operation at full wire-rate performance. See Switch Fabric (SF) Modules in a J-EX8216
Switch.
The J-EX8216 switch features 16 horizontal line card slots and supports wire-rate
performance for all packet sizes for the installed line cards. The line cards in J-EX8200
switches combine a Packet Forwarding Engine and Ethernet interfaces on a single
assembly. They are field-replaceable units (FRUs), and you can install them in the slots
labeled 0 through 15 on the front of the switch chassis. All line cards are hot-insertable
and hot-removable.
The following line cards are available for J-EX8216 switches:
8-port 10-Gigabit Ethernet SFP+ line card: This line card has eight 10-gigabit SFP+
ports on its faceplate in which you can install SFP+ transceivers. See 8-port SFP+ Line
Card in a J-EX8200 Switch.
48-port 100/1000 SFP line card: This line card has 48 1-gigabit SFP ports on its
faceplate in which you can install SFP transceivers. See 48-port SFP Line Card in a
J-EX8200 Switch.
48-port 10/100/1000 RJ-45 line card: This line card has 48 10/100/1000 Gigabit
Ethernet ports with RJ-45 connectors on its faceplate. See 48-port RJ-45 Line Card in
a J-EX8200 Switch.
The cooling system in a J-EX8216 switch consists of two hot-insertable and
hot-removable, field-replaceable unit (FRU) fan trays. Each fan tray contains nine fans.
Both fan trays install vertically on the left front of the chassis and provide side-to-side
chassis cooling and front-to-side cooling. The top and bottom fan trays are identical and
interchangeable. However, only the top fan tray cools the SF modules installed in the
rear of the chassis. See Cooling System and Airflow in a J-EX8216 Switch.
Chapter 2: Supported Hardware
33

Advertisement

Table of Contents
loading