9. To continue to refine the focus, repeat steps 6 to 8.
10. On the test pattern, check the center guide. If it is not in focus, adjust the focus on the lens.
11. Once all guides on the test pattern are in focus, tighten the set screws.
If the focus on the test pattern changes after tightening the set screws, adjust the lens focus
again and adjust the three cap screws slightly.
12. Replace the lens surround.

Replacing the high security door interlock switch

The high security door interlock switch is located directly underneath the high security door lock. It
activates when you lock or unlock the door with the high security key.
Estimated replacement time: 7 minutes
1. Turn off the projector and disconnect it from AC power.
2. Remove the top skin (on page 32).
3. Remove the high security cover (on page 40).
4. Disconnect the red and black leads from the switch.
5. Remove the two nuts securing the switch to the frame and then remove the interlock switch.
6. To replace the high security door interlock switch, complete these steps in reverse order.
CP2208-LP Service Manual
020-102263-01 Rev. 1 (09-2016)
Copyright
2016 Christie Digital Systems USA Inc. All rights reserved.
©