Replacing The Lens Mount; Replacing The Yellow Notch Filter - Christie CP2208-LP Service Manual

Hide thumbs Also See for CP2208-LP:
Table of Contents

Advertisement

Replacing the lens mount

The lens mount secures a projection lens to the projector.
Estimated time to replace: 20 minutes.
1. Center the lens to make sure the lens mount screws are accessible.
2. Turn off the light and cool the projector for at least 15 minutes.
3. Turn off the projector and disconnect it from AC power.
4. Remove the lens.
5. Remove the top skin (on page 32).
6. Remove the plate between the lens mount and the blower intake.
7. Remove the front skin (on page 33).
8. Remove the high security cover (on page 40).
9. Remove the card cage (on page 63).
10. Disconnect the nine integrated motor control board (IMCB) connectors.
11. Remove the four screws securing the light engine blower and set aside.
12. Disengage the IMCB harness assembly from the cable clamps and feed the cable assemblies
through the front of the projector.
13. Remove the four lens mount screws.
14. Remove the lens mount.
15. To replace the lens mount, complete these steps in reverse order.

Replacing the yellow notch filter

The yellow notch filter (YNF) is located in the light path just after the contrast aperture.
Estimated time to replace: 15 minutes.
1. Remove the top skin (on page 32).
2. Remove the front skin (on page 33).
3. Loosen the captive screw and remove the top skin off the YNF.
CP2208-LP Service Manual
020-102263-01 Rev. 1 (09-2016)
Copyright
2016 Christie Digital Systems USA Inc. All rights reserved.
©
Optics
79

Hide quick links:

Advertisement

Table of Contents
loading