Field
L/R Display Reference
Frame Rate N:M
L/R Display Sequence
3D Sync Polarity
Dark Time
Output Delay
Phase Delay
g) To activate the channel, tap Activate.
7. Display the RGB-12bit-Full Screen White test pattern (on page 87).
CP2208-LP Service Manual
020-102263-01 Rev. 1 (09-2016)
Copyright
2016 Christie Digital Systems USA Inc. All rights reserved.
©
Description
Select Use Line Interleave for 3D source data only.
When specified, the ICP will de-interleave each line into the
left image or right image in memory as specified. Line
interleave can be used with PsF 3D data (left and right data
for one field, then left and right data for second field).
Specifies which frame of eye data to display during a
specific display frame. This signal is referenced to the
display frame rate which is specified by the Frame Rate
N:M.
Sets how many frames to display per number of frames
that form one complete image. Increase the display frame
rate to reduce flicker from your source(s).
Defines the frame order (L-R or R-L) required for 3D
perspective. This option only has meaning when the Frame
Rate factor M is equal to 2. For this case, two input frames
of data are required to constitute a complete frame of
image data. This parameter tells the system which frames
go together to make a complete image. When using Line
Interleave as the 3D Sync Input Mode, ensure that Left
(L1R1 L2R2) is selected.
Keeps 3D stereo sync output the same as input (true) or
reversed (inverted).
True: 3D L/R sync output from GPO will match L/R sync
input.
Inverted: 3D L/R sync output from GPO will be the opposite
of sync input (left = right, right = left).
Creates a blank time interval between left and right frames
to allow for LCD shutter glasses, Z screen, or rotating 3D
wheel to synchronize the output. See Dark Time and
Output Delay Notes below. Values between 0 and 65535
are accepted. To enter the dark time value, tap the Launch
Dialog (
) icon.
The non-image time in Microseconds (μ). Offset 3D stereo
sync output in relation to dark time interval. Acceptable
values are between -32768 and 32767 are accepted where
a positive offset = delay and negative offset = start early.
To enter the output delay value, tap the Launch Dialog
(
) icon.
The degree of reference between the left and right sync
output. Values between -180 and 180 are accepted. To
enter the phase delay value, tap the Launch Dialog (
icon.