Servicing Storage Shelf Components; (Cru) - Oracle Database Appliance X7-2M Service Manual

Table of Contents

Advertisement

Note -
or SAS cable), you should wait before performing the next action to allow the system software
to fully process the event. This could take several minutes to complete.

Servicing Storage Shelf Components

Oracle Database Appliance X7-2-HA (DE3-24C), Oracle Database Appliance X6-2-HA (DE3-
24C), Oracle Database Appliance X5-2 (DE2-24C) and Oracle Database Appliance X3-2/X4-2
(DE2-24P) storage shelf components can all be replaced while the storage shelf is powered-on
and running. They include:
(CRU)" on page 79
Adding Optional Oracle Database Appliance X7-2-HA Storage
Shelf Drives (CRU)
The Oracle Database Appliance X7-2-HA storage shelf partially-populated base
Before You Begin
configuration supports 15 expansion slots for either 3.2 TB SSDs (available in five-packs)
or 10 TB HDDs (available in a fifteen-pack). These expansion slots are labeled 5-19 as seen
from the front of the system (callouts 5 through 19 in the following illustration). Note the
following:
Adding Optional Oracle Database Appliance X7-2-HA Storage Shelf Drives (CRU)
After a physical insertion or removal action of a storage shelf component (such as a disk
Upgrading the base configuration storage shelf with 3.2 TB SSDs can be performed
with the appliance running. When you expand storage, you must first add all of the disks
and then expand storage on all the new disks at the same time. Once you expand storage
to support additional disks, you cannot revert to the base configuration (no drives in
slots 5-19).
Upgrading the base configuration storage shelf with 10 TB HDDs requires that you
move the 3.2 TB SSDs from shelf storage slots 0-4 to slots 15-19. This procedure
requires powering down the appliance. In addition, this upgrade this will require that
you perform cleanup, redeploy the appliance and restore the database as described in the
Deployment and User's Guide for the appliance. Once you expand storage to support
additional disks, you cannot revert to the base configuration (no drives in slots 5-19).
Chapter 3 • Servicing CRUs That Do Not Require System Power Off
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents