Oracle Database Appliance X7-2M Service Manual page 178

Table of Contents

Advertisement

Remove PCIe Riser From Server Nodes
Caution -
discharge. This sensitivity can cause the component to fail. To avoid damage, ensure that you
follow antistatic practices as described
Prevention Measures" on page
Remove PCIe Riser From Server Nodes
Note -
2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 or Oracle Database
Appliance X6 series. Refer to the preceding chapters in this document for information on
servicing those systems.
This section describes removing a PCIe Riser from Oracle Database Appliance Version 1.
Prepare the server node for service.
1.
Attach an antistatic wrist strap.
a.
See
Measures" on page
b.
Remove the server node from the system.
Power is removed from the server node when you remove it from the system. See
"Removing Server Nodes From the System Chassis" on page
Remove the server node top cover.
c.
See
2.
If you are servicing a PCIe card, locate its position on the riser.
Disconnect any data cables connected to the cards on the PCIe riser being
3.
removed.
To disconnect a cable from a PCIe card, press the latch, push in toward the connector, and then
pull out to remove the cable.
Note the location of all cables for reinstallation later.
Ensure that the latch adjacent to the location where PCIe riser is installed is in
4.
the open (down) position [1].
If the latch is in the closed position, it prevents you from removing the PCIe riser.
178
Oracle Database Appliance Service Manual • November 2017
These procedures require that you handle components that are sensitive to static
146.
Information in this appendix does NOT apply to Oracle Database Appliance X3-
"Performing Electrostatic Discharge and Antistatic Prevention
146.
"Removing the Server Node Top Cover" on page
in"Performing Electrostatic Discharge and Antistatic
149.
147.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents