See "Powering On Oracle Database Appliance Version 1" On Page; Servicing The Pcie Card Cables (Fru) - Oracle Database Appliance X7-2M Service Manual

Table of Contents

Advertisement

Remove PCIe Card Cables From Primary HBA PCIe Card
c.
Power on the server node.
See

Servicing the PCIe Card Cables (FRU)

The Oracle Database Appliance Version 1 PCIe card cables are used to connect the internal
PCIe card, the primary HBA and a riser-mounted PCIe card, and the secondary HBA to the
motherboard. See the following sections for instructions.
The PCIe card cables are FRUs and can only be replaced by an Oracle-qualified service
technician.
"Remove PCIe Card Cables From Primary HBA PCIe Card" on page 230
"Install PCIe Card Cables for Primary HBA PCIe Card" on page 231
"Remove PCIe Card Cables From Secondary HBA PCIe Card" on page 232
"Install PCIe Card Cables for Secondary HBA PCIe Card" on page 234
Remove PCIe Card Cables From Primary HBA PCIe Card
Note -
2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 or Oracle Database
Appliance X6 series. Refer to the preceding chapters in this document for information on
servicing those systems.
This section describes removing PCIe card cables from Oracle Database Appliance Version 1.
1.
Prepare the server node for service.
Attach an antistatic wrist strap.
a.
See
Measures" on page
b.
Remove the server node from the system.
Power is removed from the server node when you remove it from the system. See
"Removing Server Nodes From the System Chassis" on page
c.
Remove the server node top cover.
230
Oracle Database Appliance Service Manual • November 2017
"Powering On Oracle Database Appliance Version 1" on page
Information in this appendix does NOT apply to Oracle Database Appliance X3-
"Performing Electrostatic Discharge and Antistatic Prevention
146.
249.
147.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents