c.
Engage the release lever by rotating it downward and slipping it under the
catch [4].
Ensure that there is no debris on the top of the CPU die.
d.
Use the syringe (supplied with the new or replacement CPU) to apply
e.
approximately 0.1 ml of thermal grease to the center of the top of the CPU.
Do not distribute the grease.
f.
Orient the heatsink so that the DIMM SIDE label on the top of the heatsink
is facing the memory modules (DIMMs) and the two captive Phillips screws
align with the mounting studs.
Each heatsink is labeled to indicate which side of the heatsink faces the memory modules
(DIMMs) when the heatsink is properly oriented.
g.
Tighten the two Phillips screws alternately two full turns at a time until the
screws are fully seated [5].
Return the server node to operation.
4.
Install the air duct.
a.
See
"Install Air Duct" on page
b.
Install the server node top cover.
See
"Install Server Node Top Cover" on page
Install the server node into the system.
c.
See
"Install Server Node Into System Chassis" on page
d.
Power on the server node.
See
"Powering On Oracle Database Appliance Version 1" on page
5.
Clear the CPU faults.
a.
Log in to the server node as root using the Oracle ILOM CLI.
b.
To view server node faults, type the following command to list all known
faults on the system:
->
show /SP/faultmgmt
196.
246.
Appendix A • Servicing the Oracle Database Appliance Version 1
Install Processor (CPU)
247.
249.
203

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Database Appliance X7-2M and is the answer not in the manual?

Questions and answers

Table of Contents