Chapter 16 – Firmware Revision History
- Added Sampler Injection Time Parameter.
Added the ability to store transaction data to the SD Card. It is saved as a flat file
with no extension, and has the BOL number appended to the filename.
All logs, reports, and transaction files will be stored in separate directories now. The
MultiLoad will create the follow directories if needed: LOGS, REPORTS, and TRANSACTIONS.
Created a Purge Routine that will search these three directories and delete files that
haven't been modified for more than 90 days.
04/09/15 TF
Fix: TDS BSW and Pressure data was formatted incorrectly if the value was a negative
number between 0 and -1. For example, "-0.2" would show up as "0.-2".
04/10/15 MTS
Fix: (revised post 4/24/15)Modified users and password activity to the following level:
[with security bypass switch on]
- the startup ("00000") password is functional regardless of users(30 sec only when
security bypass is on).
- user access level is ADMIN in that first 30 sec providing full rights to alter
parameters or users.
[with security bypass switch off]
- the startup ("00000") password is functional as a single ADMIN if no users are
created.
- user access level is ADMIN when no users are created or in play.
once a user is created (the addition of a password to a user):
- the startup ("00000") password will present the User selection screen.
- a single or the first user can only be at an ADMIN level (ML will not allow
otherwise).
- subsequent users can be added at any access level only by an ADMIN user.
- the ADMIN user is designed to be the last user to delete.
04/14/15 TF
Added new Trace Parameter: FTP Trace.
Separated the Message Logs and the Audit Logs into their own directories (AUDIT_LOGS,
MESSAGE_LOGS).
04/16/15 MTS
Fix: Allow all users to be deleted from the multiload. In all cases the last user to be
deleted will be at admin level.
04/23/15 MTS
Fix: Allow Multiload to Properly Multidrop Alibi log via the COM2 port. Previous code did
not release the communications port properly.
04/24/15 WJP
Added User Security Bypass feature on CPU board dip switch #2 ($3 if config switch, #4 if
W&M switch).
When enabled will allow full access when 00000 is used within first 30
seconds of a power up or reboot, no access is allowed after that.
Added ability to see the status of the User Security Bypass switch on the RCU diagnostics
screen.
Added the ability to read the User Security Bypass switch state in custom logic.
Added the display of warning messages on the boot screen and inserted into the message
log when the User Security Bypass, Config Mode or W&M Mode switches are active.
04/28/15 WJP
Corrected mA value in the Adtv PID trace message.
Firmware Version 3/4.31.37
501
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers
Greetings, how can multiload ll totalizers be reset?
The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.
This answer is automatically generated