Chapter 16 – Firmware Revision History
other handshake signals to the RCU or a printer alarm will be raised and prevent
loading.
01/26/08 3.28.07 WJP (sent to QA for testing)
Corrected bug that caused meter level alarms not to clear when leaving factory
calibration/analog calibration menu.
01/29/08 3.28.07 WJP (sent to QA for testing)
Corrected bug that caused unknown RTD value on powerups and other errors.
03/13/08 2.28.07 WJP
Corrected bug to properly handle and return negative API gravity. Updated
transaction retrieval, MRS, and ticket printing.
03/17/08 3.28.08 WJP
Corrected network RX task to properly handle abnormal socket terminations from
WINSOCK that return -1 from the socket read().
Bug caused SMP/ML to lockup when a WINSOCK host application abnormally
terminated.
Added ml_fcm2_tester binary output and functions to perform all digital and
analog FCM2 testing and calibration.
Corrected display of 6 digit integers on the configuration screens (min/max
preset value).
Added ability to use Temperature Module Type 3 to use 4-20mA on I/O Board or FCM
II Analog Board for Temperature Input.
Updated firmware version to 3.28.08.
03/19/08 3.28.08 WJP (QA approved and released)
Added Toptech 4-20mA status line on the V&I -> View Temperature screen.
04/04/08 3.28.09 WJP (Beta Release to D.H. to solve field blend issue)
Corrected signed/unsigned compares in ml_fcm_config.c causing blend to race out
of tolerance and alarm.
04/16/08 3.28.09 WJP (37 bit prox cards)
Updated card reader code to support HID 37 bit H10320 formatted cards (facility
code = 0).
05/07/08 3.28.09 WJP
Added Decal and Terquimsa customer logos for TTE.
06/03/08 3.28.09 WJP
Corrected bug in limit checking 1st and 2nd trip flow rates that allowed negative
target rates to ramp up flow beyond excess rate.
Corrected bug in computing lower BD rate that caused valve to "hunt" when lower
limit went negative.
06/22/08 3.28.10 WJP
Added customer supplied TransMontaigne2 logo.
Corrected bug in reading IP address information on the serial port.
Moved the Date & Time setup from the W&M Menu to the Configuration Menu.
are still logged in the W&M change log.
Updated FCM 2 tester code to use fast polling.
Updated FCM 2 tester code to display DC power output status.
Updated firmware version to 3.28.10.
Firmware Version 3/4.31.37
439
Changes
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers
Greetings, how can multiload ll totalizers be reset?
The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.
This answer is automatically generated