Chapter 16 – Firmware Revision History
Added new meter level parameters "Density Alarm Time" and "Pressure Alarm Time"
to provide a time that the value must be out of spec before raising the alarm.
Same logic as the "Temperature Alarm Time" parameter.
Updated density calculations to handle values larger than 1200.0.
Expanded range from 1200.0 to 9999.9 for Meter Level Default Density, Density
Alarm High, and Density Alarm Low.
Expanded range from 1200.0 to 9999.9 for Component Level Default Density.
Expanded range from 1200.0 to 4000.0 for Meter Level Density @ 4mA and Density
@ 20mA.
Updated RCU Setup Database version to 3.28.12.
Updated Real Time Database version to 3.28.12.
Added PetroPlus Logo for TTE.
Updated firmware version to 3.28.12.
09/5/08 3.28.12 WJP
Added support for MultiClass PIV-200 card reader to read TWIC cards returning the
card FASC-N.
Updated card reader logic to support TWIC card reads.
Added W&M_CLEAR alarm level that only allow clearing of alarm when W&M switch is
active.
Added wm_clear_errors bit to bay, preset, component, meter and additive status
(MRS command).
Added promotion_count, promoted alarm level, and alarm_count_reset_mode to the
alarm configuration.
When an alarm occurs promotion_count number of times, the alarm level is
changed to the promoted alarm level.
When the alarm_count_reset_mode condition is met, the alarm count is reset and
the alarm is returned to the base alarm level.
Reset modes can be on transaction authorization, successful alarm clearing, or
a delay of time from minutes to days of up system time.
Power cycling a system will restart the time required to return an alarm to
the base level.
Attempts to set non-auto clearable alarms to auto clear will result in the
alarm being set to driver clearable (i.e. low_flow alarm).
Added new configuration format type, ALARM_COUNT_RESET_MODE.
Updated Alarm Configuration Registers 710-714 to support new parameters, but
still accept updates in the old format.
On U710-714 attempts to set non-auto clearable alarms to auto clear will result
in the alarm being set to driver clearable (i.e. low_flow alarm).
Added alarm count to "alarm raised" log message when promotion count is
configured.
Added Additive W&M controlled parameters "W&M Inj Flt Promo Count" and "W&M Inj
Flt Reset Mode" to override registers for alarm promotion to WM_CLEAR on particular
additives.
Added W&M logging to alarm level changes when old or new alarm levels are
WM_CLEAR.
Updated Configuration->Alarm, to support the new Alarm Configurations.
Updated Views->W&M Change Log, to display the new Alarm Configuration Changes.
Updated R912 W&M Change Log to support new W&M Alarm Configuration Changes.
Removed legacy R030,U030-Card Length Register.
Removed legacy R031,U031-Card Offset Register.
Increased size of R962-Card Data from 40 characters to 80.
Updated Diagnostics->Card Reader to report new Card Data Format Error.
Firmware Version 3/4.31.37
441

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiLoad II and is the answer not in the manual?

Questions and answers

Ohadugha Nnaemeka
April 3, 2025

Greetings, how can multiload ll totalizers be reset?

1 comments:
Mr. Anderson
April 3, 2025

The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.

This answer is automatically generated

This manual is also suitable for:

Multiload ii smpMultiload ii scsMultiload ii mobile

Table of Contents

Save PDF