Chapter 16 – Firmware Revision History
03/02/07 3.27.04 WJP
Added multilingual support all driver and program mode screens (except meter
calibration screens and MAC address configuration screen).
Added "Driver Language", R008, and "Program Mode Language", R009, RCU level
parameters to select the language.
Added the format type of 21 of "Language" type (0=English, 1=Spanish).
Configuration parameter lengths have been increased from 20 to 30 characters.
All levels of configuration screens are wider now to accommodate foreign
languages.
Configuration prompts will be returned in the language specified by "Program Mode
Language" parameter.
Configuration parameters descriptions, ranges and defaults, as well as status and
key prompts have been moved into ROM.
Updates to language prompt registers u000-099, u101xxx, u102xxx, u103xxx, u104xxx
no longer supported.
Removed all configurable prompt registers, 700xxx, except ones used by TMS for
overseas customers (70000x-70004x, 70007x, 70019x, 70020x, 70028x, 70035x).
Removed 701(status) and 705(additive status) label registers.
Removed 720(key prompt) label registers.
Alarm Label registers (R7100xx-R7140xx) will return the alarms in the language
specified by "Program Mode Language".
Alarm Labels registers (U7100xx-U7140xx) will only update the labels on
permissives (U711001-711008, U712001, U712001, U713001, U714001).
API tables 23E 'a', 59E 'b' have been added to support correction to 20C.
Moved integer front end of API table 24E to a separate routine to allow 23E and
59E to access the 24E floating point calculations without rounding.
Corrected Table 24E start point.
API tables can now return corrected_relative_density and corrected_density.
Default configurable prompts are now disabled.
Preset status and component status formatting has changed to accommodate foreign
languages.
Updated W&M change log to trace parameter index, and not memory index to
parameter, to handle ROM placement of parameters.
Updated firmware version to 3.27.04.
Updated database version to 3.27.04 for RCU Setup Database, Real Time Database,
and Equipment Database and W&M Log & Totalizer Database.
03/02/07 3.27.05 WJP (released to QA for testing)
Marked parameters not relevant to the SMP builds to be NA.
All NA parameters are reset to the default value on bootup.
when this occurs.
Updated code so that writes to NA registers returns an invalid parameter code.
Added "W&M Key FCM#" and "Program Key FCM#" as RCU level parameters for external
connection of W&M and program switches.
internal inputs/DIP switches and can be viewed on the RCU Diagnostic screen.
Incorporated final review of all Spanish Transactions.
Added Multilingual Product Graphic capability with English and Spanish versions
for the ML II, ML II 1-Arm, MultiLoad II SMP graphics.
Corrected SMP bug when the program key was not active and the Load Screen Timeout
occurs, the screen would stop updating and keypad would stop functioning until an
end transaction signal was received.
Updated firmware version to 3.27.05.
Updated database version to 3.27.05 for Equipment Database.
Per PEMEX, Calculation of CTL from Table 59E is calculated as CTL =
Measured_Density / Corrected Density from API Table 59E.
03/23/07 3.27.06 WJP (released to QA for testing)
Corrected bug in transaction archive not recording the ending time.
Firmware Version 3/4.31.37
Correction did not affect 24E calculations.
Status of these inputs are ORed with
A message is logged
435

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiLoad II and is the answer not in the manual?

Questions and answers

Ohadugha Nnaemeka
April 3, 2025

Greetings, how can multiload ll totalizers be reset?

1 comments:
Mr. Anderson
April 3, 2025

The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.

This answer is automatically generated

Subscribe to Our Youtube Channel

This manual is also suitable for:

Multiload ii smpMultiload ii scsMultiload ii mobile

Table of Contents

Save PDF