Toptech Systems MultiLoad II User Manual page 446

Table of Contents

Advertisement

Chapter 16 – Firmware Revision History
Added Legacy ACR test to Factory Menu.
Expanded Configuration Prompts Register, r100-104, to return a max of 90 bytes
and a default of 30 bytes (instead of 20 bytes) to support UTF-8 worst case.
Increased size of Alarm Names storage to handle UTF-8 characters.
Expanded Alarm Configuration Registers, R/U710-714, to return 30, instead of 10
bytes to support UTF-8 worst case.
Expanded Modbus Alarm Configuration Registers, 2500-2599, to return 15, instead
of 10 bytes to support UTF-8.
Updated Alarm Setup Screen to properly display UTF-8 strings.
Updated RCU Setup Database version to 3.29.01.
Added W&M logging of firmware updates by monitoring the current firmware type,
version and build date on startup (Canada & US W&M req.).
Added W&M logging of when any database is reset to factory defaults.
Expanded W&M Log Register, R912, to support Firmware Updates and Factory Default
events.
Updated View W&M Log to support Firmware Updates and Factory Default events.
Updated start_clock() to immediately poll RTC for current date/time at startup to
prevent W&M and Event logs from reporting 00/00/00 00:00:00.
Updated W&M Log and Totalizer Database version to 3.29.01.
Added lcd_driver code to read the LCD device ID from display color lines.
Binary set of 10K pull down resistors on Blue color lines identify LCD display
model connected.
0x0000 = 8.4 VGA with limited 50-100% on backlight dimming, no pull down
resistors on color lines.
0x0001 = 8.4 VGA with full 0-100% on backlight dimming, 10K Pull Down on
Display Board Blue 1 (LSB) color line.
Corrected bug in Output Pulse Port processing where specification of port 10
would not send pulses to IO board.
port 10 on IO boards.
Removed qml, qml1, qmlm targets from the Makefile build script.
Updated firmware version to 3.29.01.
4/6/09 3.29.01 WJP (released for testing)
Corrected alarm count to allow up to promo count alarm clears before promoting to
new level on next alarm.
Moved Blend Check Start Vol and Blend Check Restart Vol under Conditional W&M
control.
Corrected U600 register to correctly parse 0, 8 and 16 lockout bits on stand
along card database.
8/5/09 3.29.02 WJP
Correct bug in card reader code that prevented correct identification of some
corporate 1000 HID cards.
Updated simulation display terminal code to display utf-8 Unicode and text
foreground/background colors.
Added "Toptech Product ID French" graphic screens.
Added "Total Oil" and various other customer logo graphic screens.
Replaced "Toptech Global Solutions" with "Toptech Systems" graphic screen.
Updated "MultiLoad" (English, Spanish, and French) product ID graphic screens.
Updated code to bring in product ID graphics as raw files in /rcutlc4/bmp
directory instead of compiled C const structs.
Updated U/R 990 and 991 registers to work with new .raw file method.
Firmware Version 3/4.31.37
Workaround was previously to specify port 1 for
Previously promoted on promo count alarm occurrence.
446

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiLoad II and is the answer not in the manual?

Questions and answers

Ohadugha Nnaemeka
April 3, 2025

Greetings, how can multiload ll totalizers be reset?

1 comments:
Mr. Anderson
April 3, 2025

The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.

This answer is automatically generated

Subscribe to Our Youtube Channel

This manual is also suitable for:

Multiload ii smpMultiload ii scsMultiload ii mobile

Table of Contents

Save PDF