Chapter 16 – Firmware Revision History
03/07/2013 PS
Enhancement of Custom Logic supports now Temperature, BSW, Gravity, Relative
Density, Density, Pressure, Volumes
Enhancement of Custom Logic supports now Timers Start and Stop Delay.
03/07/2013 WJP
Added display of Battery Voltage and Temperature on RCU Diagnostics screen (only
if CPU board supports the feature).
03/08/2013 PS
Enhancement of Register800 to always transaction read of
api_expansion_coef_tenths,
bsw_hund, alibilog_alarm
03/08/2013 PS
Added Bay Number to the Web-Interface
03/11/2013 PS
Fix Ticket Print: Measure used was on totalizer line correct for gross , but
incorrect for net.
Also allow totalizer to be shown with max value of 999999999
Fix Measure used for Additive Totalizer Line was missing
03/12/2013 PS
Added in Custom Logic the State for Preset,Meter,Component (High Flow, Low Flow,
....)
Added in Custom Logic under Rcu Real Time Parameters the Date and Time value
03/12/2013 WJP
Corrected bug on SMP firmware builds where the editing of parameters on the RCU
General screen edited the wrong parameter.
03/12/2013 WJP
Update TDS 3po checksum routine to stop converting all incoming and outgoing data
to upper case.
03/18/2013 WJP
Corrected bug (may have been created on 5/17/2011) in processing and prompting
for PIN numbers when processing mode is set to Stand-Alone.
03/19/2013 WJP
Added ability to support two different serial ports set to host mode.
03/21/2013 WJP
Added
MRTDpppddd
specified preset, archived after clearing each batch.
03/29/2013 WJP
Added Batch Number (1-9,999,999) to the transaction archive details.
Firmware Version 3/4.31.37
corrected_densitygravity,
command
to
directly
volume_correction_factor,
read
the
transaction
472
details,
for
a