Chapter 16 – Firmware Revision History
Pressure value is now in hundredths. Communication will only give whole values
for backwards compatibility reasons.
9/17/2014 PS
Remove logic that stores previous IP-address. This could cause power-cycling of
the unit because unusable IP address is restored.
Remark: By removing network cable and entering correct IP-address the issue gets
resolved.
Added to the MRTD command the pressure in hundredths value. Value was also added
to the R800 transaction register.
9/26/2014 MTS
Fix W&M bolts now required to be out before setting Factory Defaults from the
command console, and the Main Menu.
9/30/2014 TF
Fix DNS Server lookup. Moved the DNS lookup into the background tasks, it was
previously in the Main Task which could cause the unit to pause for about 20
seconds.
10/01/2014 PS
Increased MultiLoad firmware number to 18.
10/04/2014 PS
Change UAP Order Processing to support multiple suppliers with same order number.
10/14/2014 PS
Change API TEC to use expansion coefficient instead of the api gravity. When
upgrading firmware the value of the api gravity needs to be copied into the
expansion coefficient.
10/15/2014 TF
Fix Analog Meter Flow Rate. If the Meter type is Analog, Krohne, or Micromotion
and the flow rate was set to be calculated by hour. The MultiLoad previously
displayed the flow rate per minute even if configured to display per hour.
Fix the Web Interface task. In version 4.31.17 the web interface could
potentially stop working after prolonged use; the only fix was to power cycle the
unit
10/15/2014 PS
Fix API Table D1555 coefficients of Benzene, Styrene, Oxylene and Pxylene.
10/23/2014 WJP
Corrected network_connect_occurred() to return a one-shot value.
rcu_ditto to not work on TMS5 and TMS 6 systems.
Increased firmware version to x.31.19.
10/15/2014 PS
Increased firmware version to x.31.20.
Added OpenSSL version number to Network Screen.
Enhancement: Added recipe selection for standalone mode via fcm inputs.
Enhancement: Added recipe output to show the selected preset authorized product.
Upgrade OpenSSL to version 1.0.1i
Firmware Version 3/4.31.37
495
This bug caused
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers
Greetings, how can multiload ll totalizers be reset?
The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.
This answer is automatically generated