Chapter 16 – Firmware Revision History
Updated prompt script date error messages to clearly indicate the database and
field that is causing the error.
Updated custom prompt script with comments and changes some variable names to
more easily follow the logic.
Updated custom prompt script to clear previous prompt data on each prompt to
prevent previous data from being preserved when no entry is given.
Still an issue with early AM time checks in UAP script.
Still an issue with prompt script Previous key when certain prompts are not
required.
On custom prompt processing logic, renamed some variables to make code more
readable.
5/17/2014 PS
UAP any date checking was using 12:00:00 (noon) as a reference now its 00:00:00
(morning).
5/19/2014 PS
Fix: During clearing of a batch and leakage of a valve it was possible that the
meter volume would be bumped and the next batch would have a different preset
volume against the meter volume.
5/21/2014 WJP
Fixed bug in UAP picklist routine where stray characters could appear after data.
5/22/2014 PS
Fix: Standalone as UAP bol will not print vcf, ctl and cpl when it is a saleable
product line.
Fix: Resolved an issue with the 10 digit UAP prompts for customer, account, etc.
that would not work if the entered or picklist number was over 9 digits in length.
Fix: UAP when loading between 00:00:00 and 00:59:00 in the morning it was
possible to see a load denied.
5/23/2014 PS
Enhancement: In normal condition any alarm during a batch will make all alibilog
batches none legally relevant. Now it will only affect 1 batch.
Enhancement: If any alarm would occur when the batch is finished like a preset
permissive MultiLoad would make the alibilog batch also none legally relevant. By
using the alarm batch mask
function we allow to mask the alibilog alarm when not flowing, during flow we
always need to report the issue.
Enhancement: Simulation webpage will support all type of fcms , depending on
which fcm type is configured.
6/03/2014 PS
UAP timeout changed from 2 to 5 seconds.
Added freight Bol functionality to UAP.
Enhancement: Allow loopback test on each communication port.
6/05/2014 PS
Fix: The MRTD command as MRS command as the transaction retrieve command has been
changed from 5 to 6 long for any correction_factor value.
Enhancement: Access ID Screen is enhanced to show and change all values.
6/06/2014 PS
Fix: Any sprintf %04x is now limited with 0xFFFF.
6/07/2014 PS
Firmware Version 3/4.31.37
489

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiLoad II and is the answer not in the manual?

Questions and answers

Ohadugha Nnaemeka
April 3, 2025

Greetings, how can multiload ll totalizers be reset?

1 comments:
Mr. Anderson
April 3, 2025

The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.