Chapter 10– Views and Inquiries
Bol#
Bol # sequence number from MultiLoad II
Detail
Number of details of 1 transaction (1 to 99)
Batch#
Batch# sequence number from MultiLoad II for each loaded batch the number will be
increased by 1
Preset
Preset or Arm which was used during loading
Component
Component which is loaded
Type
Product Type: 1=Saleable Product Recipe; 2=Component; 3=Additive; 4=Meter,
5=Preset Totalizer, 6=Meter Totalizer, 7=component Totalizer, 8=Additive Totalizer
Product
Name of the Product (Saleable, Component , Additive)
Alarm
If their was an alarm for that transaction
Gross
Gross Volume.
Net
Net Volume.
Mass
Mass
Temperature
Temperature of the load
Pressure
Pressure of the load
BSW
Bottom Sediment Water (percentage %)
Density
Density of the load
Relative
Relative Density of the load
Density
API Gravity
API Gravity of the load
API Table
Name of the API-table that is used for that batch
Vcf
Vcf- factor which is used during the loading
Ctl
Temperature correction factor
Cpl
Pressure correction factor
Firmware Version 3/4.31.37
VIEW TRANSACTION DETAIL DETAILS
Bol#:
00001 Detail#:
Batch#:
0000005
Preset:
Type:
Preset Product:
Alarm:
Gross:
499.54 Net:
Mass:
0.0
Temperature:
Pressure:
BSW:
VCF(None):
CTL:
1.0000 CPL:
Next
Prev
00001
01 Component:
PRD001
No
499.54
+28.5
+0.0
+0.0
1.0000
1.0000
Exit Enter
01
341
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers
Greetings, how can multiload ll totalizers be reset?
The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.
This answer is automatically generated