Chapter 9 – Weights & Measures
Table
ASTM1250-
2004 Table 6B
ASTM1250-
2004 Table 6C
ASTM1250-
2004 Table 6D
ASTM1250-
2004 Table 6X
ASTM1250-
2004 Table 24A
ASTM1250-
2004 Table 24B
ASTM1250-
2004 Table 24C
Firmware Version 3/4.31.37
Description
This table provides CTL factors for correcting volumes of gasolines at observed
temperatures to the volume at 60 F, using the method outlined in Chapter 11.1.6.1 of the
2004 standard. Use this table if the following conditions exist:
The liquid is a refined product
API Gravity @ 60 F is known
Reference Temperature is 60 F
This table provides CTL factors for correcting volumes of petroleum liquids at observed
temperatures to the volume at 60 F, using the method outlined in Chapter 11.1.6.1 of the
2004 standard. Use this table if the following conditions exist.
The liquid is a refined product or crude oil
Coefficient of Expansion @ 60 F is known
Reference Temperature is 60 F
This table provides CTL factors for correcting volumes of lube oils at observed temperatures
to the volume at 60 F, using the method outlined in Chapter 11.1.6.1 of the 2004 standard.
Use this table if the following conditions exist.
The liquid is a lube oil
API Gravity @ 60 F is known
Reference Temperature is 60 F
This table provides CTL factors for correcting volumes of a petroleum product at observed
temperatures. This table allows specifying the commodity being measured, the coefficient
of expansion, the reference temperature, and units of measure for density, pressure, and
temperature.
This table provides CTL factors for correcting volumes of crude oil at observed
temperatures to the volume at 60 F, using the method outlined in Chapter 11.1.6.1 of the
2004 standard. Use this table if the following conditions exist:
The liquid is crude oil
Relative Density at 60 F is known
Reference Temperature is 60 F
This table provides CTL factors for correcting volumes of gasolines at observed
temperatures to the volume at 60 F, using the method outlined in Chapter 11.1.6.1 of the
2004 standard. Use this table if the following conditions exist:
The liquid is a refined product
Relative Density at 60 F is known
Reference Temperature is 60 F
This table provides CTL factors for correcting volumes of petroleum liquids at observed
temperatures to the volume at 60 F, using the method outlined in Chapter 11.1.6.1 of the
2004 standard. Use this table if the following conditions exist.
The liquid is a refined product or crude oil
Coefficient of Expansion @ 60 F is known
Reference Temperature is 60 F
289
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers
Greetings, how can multiload ll totalizers be reset?
The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.