Chapter 16 – Firmware Revision History
11/02/2012 PS
Add ability of EOD-Report to trigger via Modbus
11/04/2012 WJP
Added RCU general configuration parameter (R/U076) Ethernet HTTP "admin" Password
(default "'Toptech")
Added RCU general configuration parameter (R/U077) Ethernet HTTP "user" Password
(default "toptech")
11/06/2012 PS
Integrated a Low Flow Proving Rate, so during proving another low flow rate can
be giving instead of using
the preset low flow rate
11/6/2012
Corrected bug in UAP script with respect to picklist paging.
calls in the prompt script must NOT have commands following it on the same line.
11/7/2012 WJP
Corrected UAP bug where a blank driver PIN was still prompted for when pin_req
was not "N".
Updated UAP LUA script error processing to display message as well as writing it
into the message log.
Correct web file upload naming to correctly deal with windows "\"s in filenames.
11/7/2012 PSFix transaction viewer via web-interface. Values were not reflected
correctly.
Density,
Measurement approved
11/9/2012 PS
Remove Time of UAP R000 register
11/13/2012 WJP
Corrected UAP bug that caused TDS transactions and BOLs to omit data fields when
special characters, for example ""(quotes), appeared in the UAP database values.
11/19/2012 PS
fix bug in reading via Modbus relative density
add new functionality of BSW real-time analog input , all parameters, transaction
viewer also store value, alibilog , ticket builder, reading live BSW via MRS,
Modbus functional, bsw can be back-calculated blending
add new functionality of API Gravity real-time analog input, all parameters,
reading live API Gravity via MRS, Modbus functional, api gravity can be back-
calculated blending
add new functionality to simulate analog input each fcm number will bump the
current with 300mA
changed meter screens logic that only 1 density type is shown at a time: api
gravity or relative density or density
changed sd_card routine that we store all parameters even if higher than 100
registers
changed boot config check that we check more than 100 registers for each level
Firmware Version 3/4.31.37
Relative,
Pressure,
possible
hundredths
467
PickListHandle()
mode,
Alarm,
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers
Greetings, how can multiload ll totalizers be reset?
The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.
This answer is automatically generated