Chapter 16 – Firmware Revision History
Enhancement: Added FTP client report file push from a specific folder and file prepend
char. Currently the folder is "reports" and the prepended character is '@'. Once pushed,
the @ symbol is removed.
Fix: The archive log file potential to assert or crash if the log message has a 0 month
or 0 day timestamp.
03/17/2015 TF
Changed all open() functions that use the O_CREATE flag to also use
S_IRWXO|S_IRWXU|S_IRWXG modes which enable read and write access of files.
03/18/2015 TF
Added the ability to store beginning totalizers to a transaction.
Added Sampler CSV Report.
Added Meter CSV Report.
Added Bay ID, Meter ID, Beginning Totalizers, Ending Totalizers, Observed Gross, and
Observed Temp to the Transaction Report.
Added a start and end time to all reports.
Added automated reports:
- All three reports can generate a Daily and Monthly report.
- New Configuration Screen was added called "Reports"
- New Configuration Parameters for each report
* Daily Report Enabled
* Daily Report Time Trigger
* Monthly Report Enabled
* Monthly Report Day Trigger
* Monthly Report Time Trigger
- Every fifteen minutes we check to see if a report is needed to be created
- If FTP server is enabled then we immediately fire off the FTP task after a report is
created.
03/24/2015 MTS
Enhancement: (revised post 4/24/15) Added User security levels and parameter based
security levels.
At a high level, the ability for a user to modify a parameter will now be judged
based from the users own security level against the parameters security level.
- user and parameter levels are 1 - 10 with 10 being an ADMINISTRATOR level.
- if a user's level is equal to or greater than the parameter level, the user has the
rights to modify the subject parameter.
- on the contrary, if a user level is less than the parameter level, the user will be
notified on the screen of the denial and level that is required.
- Access levels are like user levels when a parameter is being accessed by a means other
than front panel (ex: network, serial com, Modbus...)
- Parameter security levels may be discrete levels per parameter such as "Equipment
Setup" and "Reports" (RCU Setup/Display Help must be enabled to view/change).
...or Group based levels where one setting will cover multiple like parameters such as
alarms, network settings, trace settings - etc.
- Security level settings themselves can ONLY be altered by an ADMIN level user or access
entity.
- the single default user of multiload has all access.
04/01/15 TF
Enhancement: Made the FTP task scan through all directories for files that need to send
to the FTP server.
04/06/15 TF
Fix: The injection time for all Samplers was hard coded for 0 milliseconds.
Firmware Version 3/4.31.37
500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiLoad II and is the answer not in the manual?

Questions and answers

Ohadugha Nnaemeka
April 3, 2025

Greetings, how can multiload ll totalizers be reset?

1 comments:
Mr. Anderson
April 3, 2025

The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.

This answer is automatically generated

This manual is also suitable for:

Multiload ii smpMultiload ii scsMultiload ii mobile

Table of Contents

Save PDF