Chapter 16 – Firmware Revision History
Enhancement: Added FTP client report file push from a specific folder and file prepend
char. Currently the folder is "reports" and the prepended character is '@'. Once pushed,
the @ symbol is removed.
Fix: The archive log file potential to assert or crash if the log message has a 0 month
or 0 day timestamp.
03/17/2015 TF
Changed all open() functions that use the O_CREATE flag to also use
S_IRWXO|S_IRWXU|S_IRWXG modes which enable read and write access of files.
03/18/2015 TF
Added the ability to store beginning totalizers to a transaction.
Added Sampler CSV Report.
Added Meter CSV Report.
Added Bay ID, Meter ID, Beginning Totalizers, Ending Totalizers, Observed Gross, and
Observed Temp to the Transaction Report.
Added a start and end time to all reports.
Added automated reports:
- All three reports can generate a Daily and Monthly report.
- New Configuration Screen was added called "Reports"
- New Configuration Parameters for each report
* Daily Report Enabled
* Daily Report Time Trigger
* Monthly Report Enabled
* Monthly Report Day Trigger
* Monthly Report Time Trigger
- Every fifteen minutes we check to see if a report is needed to be created
- If FTP server is enabled then we immediately fire off the FTP task after a report is
created.
03/24/2015 MTS
Enhancement: (revised post 4/24/15) Added User security levels and parameter based
security levels.
At a high level, the ability for a user to modify a parameter will now be judged
based from the users own security level against the parameters security level.
- user and parameter levels are 1 - 10 with 10 being an ADMINISTRATOR level.
- if a user's level is equal to or greater than the parameter level, the user has the
rights to modify the subject parameter.
- on the contrary, if a user level is less than the parameter level, the user will be
notified on the screen of the denial and level that is required.
- Access levels are like user levels when a parameter is being accessed by a means other
than front panel (ex: network, serial com, Modbus...)
- Parameter security levels may be discrete levels per parameter such as "Equipment
Setup" and "Reports" (RCU Setup/Display Help must be enabled to view/change).
...or Group based levels where one setting will cover multiple like parameters such as
alarms, network settings, trace settings - etc.
- Security level settings themselves can ONLY be altered by an ADMIN level user or access
entity.
- the single default user of multiload has all access.
04/01/15 TF
Enhancement: Made the FTP task scan through all directories for files that need to send
to the FTP server.
04/06/15 TF
Fix: The injection time for all Samplers was hard coded for 0 milliseconds.
Firmware Version 3/4.31.37
500
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers
Greetings, how can multiload ll totalizers be reset?
The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.
This answer is automatically generated