Chapter 16 – Firmware Revision History
Remove ability to build special UAP MultiLoad builds.
Remove ability to build ml_uap_sim from the Makefile.
Remove UAP special build label.
Correct #ifdef TDS_INTERFACE/#endif alignments in source.
Correct size of returned LUA Data in web transaction viewer.
On ml_tds_3op and ml_db, added ability to selectively start or stop tasks.
Updated database viewer to return if ml_db has not started.
Corrected UAP BOL duplicate label to use transaction_printed_bit_table.
Only include Local Databases item on Program Mode Menu when Processing Mode is
set to UAP.
Delay processing first TDS_3PO call (1 minute) until after the ml_db has started
(5 seconds)
12/09/2012 PS
Change default Meter Archive timeout and host down timeout from 30 to 120 seconds
13/12/2012 PS
UAP Fix when driver and card number are not equal then reprint doesn't work,
because database has driver number, reprint search on card number
UAP Fix alignment issue on Reprint Prompt
12/17/2012 PS
New enhancement Low Flow Start Volume Based on Percentage
12/17/2012 PS
Enhancement on UAP ticket number Webpage, Transaction Viewer and BOLs
12/17/2012 PS
Enhancement on UAP ticket date change be change to MM/DD/YY or DD/MM/YY
12/19/2012 WJP - Release to Customer
Correct Print_Blend_Details so when:
0 - Exclude components, additives and meters.
1 - Include components, additives and meters(only when meters are needed).
2 - Include components, additives and meters(always include meters, even when
not needed).
Updated Low Flow Start Volume to use the greater or either the configured Low
Flow Start Volume or the computed Low Flow Start Volume by Percentage.
Low Flow Restart Volume always uses the configured Low Flow Restart Volume.
12/24/2012 PS
Enhance Network Menu combining parameters under a new webpage menu
Add new Network Printer Menu
12/25/2012 PS
Enhance Modbus interface that all transaction values are readable
api_expansion_coef_tenths
corrected_densitygravity
volume_correction_factor
bsw_hund
alibilog_alarm
12/26/2012 PS
Restrict low flow start volume to 65535 when using low flow percentage
12/29/2012 PS
New feature deadman with input and output signal, deadman interval timer, deadman
warning timer.
Firmware Version 3/4.31.37
469
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers
Greetings, how can multiload ll totalizers be reset?
The resettable totalizers on the Toptech Systems MultiLoad II can be reset using the CLR (Clear) key. Non-resettable totalizers cannot be reset.
This answer is automatically generated