Adapt The Default Setting Of The Terminal Strip - Siemens SINAMICS G120 Operating Instructions Manual

Low voltage converters built-in and wall mounting units with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

6.3

Adapt the default setting of the terminal strip

In the inverter, the input and output signals are interconnected with specific inverter functions
using special parameters. The following parameters are available to interconnect signals:
● Binectors BI and BO are parameters to interconnect binary signals.
● Connectors CI and CO are parameters to interconnect analog signals.
This chapter describes how you adapt the function of individual inverter inputs and outputs
using binectors and connectors.
Converter with the CU230P-2 Control Units
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257946B AE
Advanced commissioning
6.3 Adapt the default setting of the terminal strip
197

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120p

Table of Contents