Installing
4.3 Installing Power Modules
Table 4-8
Frame size
FSD without filter
FSD with filter
FSE without filter
FSE with filter
FSF without filter
FSF with filter
You can mount the Power Modules without any lateral cooling air clearance. For tolerance reasons,
1)
we recommend a lateral clearance of approx. 1 mm.
70
Drilling dimensions, cooling clearances and fixing
Drilling dimensions [mm] Cooling air clearances [mm]
b
h
235
325
235
419
235
405
235
451
300
598
300
899
c
Top
Bottom
11
300
300
11
300
300
11
300
300
11
300
300
11
350
350
11
350
350
Converter with the CU230P-2 Control Units
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257946B AE
Fixing/torque
1)
[Nm]
Front
100
4 x M6 / 6.0
100
4 x M6 / 6.0
100
4 x M6 / 10
100
4 x M6 / 10
100
4 x M8 / 13
100
4 x M8 / 13