Advanced commissioning
6.15 Selecting physical units
● p0505 = 3: US system of units
Torque [lbf ft], power [hp], temperature [°F]
● p0505 = 4: System of units, referred/US
Represented as [%]
Special features
The values for p0505 = 2 and for p0505 = 4 - represented in the converter - are identical.
However, the reference to SI or US units is required for internal calculations and to output
physical variables.
For variables, which cannot be represented as [%], then the following applies:
p0505 = 1 ≙ p0505 = 2 and p0505 = 3 ≙ p0505 = 4.
In the case of variables whose units are identical in the SI system and US system, and which
can be displayed as a percentage, the following applies:
p0505 = 1 ≙ p0505 = 3 and p0505 = 2 ≙ p0505 = 4.
Reference variables
There is a reference variable in the converter for most parameters with physical units. When
the referred representation [%] is set, then the converter scales the physical variables based
on the particular reference variable.
When the reference variable changes, then the significance of the scaled value also changes.
Example:
● Reference speed = 1500 rpm → fixed speed = 80 % ≙ 1200 rpm
● Reference speed = 3000 rpm → fixed speed = 80 % ≙ 2400 rpm
For each parameter you can find the associated reference variable for scaling in the List
Manual. Example: r0065 is scaled with reference variable p2000.
If scaling is not specified in the List Manual, then the converter always represents/displays the
parameter unscaled (not normalized).
Groups of units
The parameters associated with the selection of a physical unit, belong to different groups of
units.
You can find the associated group of units in the List Manual for each parameter. Example:
r0333 belongs to unit group 7_4.
An overview of the unit groups and the possible physical units can also be found in the List
Manual.