Test Operation Mode In Mr Configurator2 - Mitsubishi Electric MR-J4-10B(-RJ) Instruction Manual

General-purpose ac servo melservo-j4 sscnet /h interface mr-j4 series servo amplifier
Table of Contents

Advertisement

4. STARTUP

4.5.1 Test operation mode in MR Configurator2

(1) Test operation mode
(a) Jog operation
Jog operation can be performed without using the servo system controller. Use this operation with
the forced stop reset. This operation may be used independently of whether the servo is on or off
and whether the servo system controller is connected or not.
Exercise control on the jog operation screen of MR Configurator2.
1) Operation pattern
2) Operation method
When the check box of "Rotation only while the CCW or CW button is being pushed." is
checked.
When the check box of "Rotation only while the CCW or CW button is being pushed." is not
checked.
POINT
When the test operation mode is selected with the test operation select switch
(SW2-1), the SSCNET III/H communication for the servo amplifier in the test
operation mode and the following servo amplifiers is blocked.
Item
Speed [r/min]
Acceleration/deceleration
time constant [ms]
Operation
Forward rotation start
Reverse rotation start
Stop
Forced stop
Operation
Forward rotation start
Reverse rotation start
Stop
Forced stop
initial value
200
1000
Keep pressing "Forward".
Keep pressing "Reverse".
Release "Forward" or "Reverse".
4 - 15
Setting range
0 to max. speed
0 to 50000
Screen control
Click "Forced stop".
Screen control
Click "Forward".
Click "Reverse".
Click "Stop".
Click "Forced stop".

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents