Earth-Leakage Current Breaker - Mitsubishi Electric MR-J4-10B(-RJ) Instruction Manual

General-purpose ac servo melservo-j4 sscnet /h interface mr-j4 series servo amplifier
Table of Contents

Advertisement

11. OPTIONS AND PERIPHERAL EQUIPMENT

11.15 Earth-leakage current breaker

(1) Selection method
High-frequency chopper currents controlled by pulse width modulation flow in the AC servo circuits.
Leakage currents containing harmonic contents are larger than those of the motor which is run with a
commercial power supply.
Select an earth-leakage current breaker according to the following formula, and ground the servo
amplifier, servo motor, etc. securely.
To minimize leakage currents, make the input and output wires as short as possible, and keep a
distance of 30 cm or longer between the wires and ground.
Rated sensitivity current ≥ 10 • {Ig1 + Ign + Iga + K • (Ig2 + Igm)} [mA] ···································· (11.1)
Ig1: Leakage current on the electric channel from the earth-leakage current breaker to the input
terminals of the servo amplifier (Found from Fig. 11.13.)
Ig2: Leakage current on the electric channel from the output terminals of the servo amplifier to the servo
motor (Found from Fig. 11.13.)
Ign: Leakage current when a filter is connected to the input side (4.4 mA per one FR-BIF(-H))
Iga: Leakage current of the servo amplifier (Found from table 11.5.)
Igm: Leakage current of the servo motor (Found from table 11.4.)
Fig. 11.13 Example of leakage current per km (lg1, lg2) for CV cable run in metal conduit
Wire
Noise filter
NV
Wire
Servo
amplifier
Ig1
Ign
Iga
Ig2
120
100
80
60
40
20
0
2
3.5 8
Cable size [mm ]
200 V class/100 V class (Note)
Note. "Ig1" of 100 V class servo amplifiers will be 1/2 of 200 V class servo amplifiers.
11 - 89
Earth-leakage current breaker
Type
M
Models provided with
harmonic and surge
Igm
reduction techniques
General models
5.5 14
38100
22
60 150
30
80
2
Mitsubishi
K
Electric
products
NV-SP
NV-SW
NV-CP
1
NV-CW
NV-HW
BV-C1
NFB
3
NV-L
120
100
80
60
40
20
0
2
5.5
14
38
100
3.5
8
22
60
150
30
80
Cable size [mm ]
2
400 V class