17. APPLICATION OF FUNCTIONS
(2) Extension control 2 parameters ([Pr. PX_ _ ])
CAUTION
No.
Symbol
PX01
**J3EX
J3 extension function
PX02
XOP1
Function selection X-1
PX03
VRFTX
Vibration suppression control tuning mode (advanced vibration
suppression control II)
PX04
VRF21
Vibration suppression control 2 - Vibration frequency
PX05
VRF22
Vibration suppression control 2 - Resonance frequency
PX06
VRF23
Vibration suppression control 2 - Vibration frequency damping
PX07
VRF24
Vibration suppression control 2 - Resonance frequency damping
PX08
VRF21B Vibration suppression control 2 - Vibration frequency after gain switching
PX09
VRF22B Vibration suppression control 2 - Resonance frequency after gain
switching
PX10
VRF23B Vibration suppression control 2 - Vibration frequency damping after gain
switching
PX11
VRF24B Vibration suppression control 2 - Resonance frequency damping after
gain switching
PX12
PG1B
Model loop gain after gain switching
PX13
*XOP2
Function selection X-2
PX14
OTHOV
One-touch tuning - Overshoot permissible level
PX15
For manufacturer setting
PX16
PX17
NH3
Machine resonance suppression filter 3
Never make a drastic adjustment or change to the parameter values as doing so
will make the operation unstable.
Do not change the parameter settings as described below. Doing so may cause
an unexpected condition, such as failing to start up the servo amplifier.
Changing the values of the parameters for manufacturer setting
Setting a value out of the range
Changing the fixed values in the digits of a parameter
When you write parameters with the controller, make sure that the control axis No.
of the servo amplifier is set correctly. Otherwise, the parameter settings of another
axis may be written, possibly causing the servo amplifier to be an unexpected
condition.
POINT
The parameter whose symbol is preceded by * is enabled with the following
conditions:
*: After setting the parameter, cycle the power or reset the controller.
**: After setting the parameter, cycle the power.
Abbreviations of J3 compatibility mode indicate the followings.
Standard: Standard (semi closed loop system) use of the rotary servo motor
Full.: Fully closed loop system use of the rotary servo motor
Lin.: Linear servo motor use
DD: Direct drive (DD) motor use
Name
17 - 15
compatibility
mode
Initial
Unit
value
0000h
0000h
0000h
100.0
[Hz]
100.0
[Hz]
0.00
0.00
0.0
[Hz]
0.0
[Hz]
0.00
0.00
0.0
[rad/s]
0001h
0
[%]
0000h
0000h
4500
[Hz]