11. OPTIONS AND PERIPHERAL EQUIPMENT
(5) Other precautions
(a) When using the FR-CV-(H), always install the dedicated stand-alone reactor (FR-CVL-(H)). Do not
use the power factor improving AC reactor (FR-HAL-(H)) or power factor improving DC reactor (FR-
HEL-(H)).
(b) The inputs/outputs (main circuits) of the FR-CV-(H) and servo amplifiers include high-frequency
components and may provide electromagnetic wave interference to communication equipment (such
as AM radios) used near them. In this case, interference can be reduced by installing the radio noise
filter (FR-BIF(-H)) or line noise filter (FR-BSF01, FR-BLF).
(c) The overall wiring length for connection of the DC power supply between the FR-CV-(H) and servo
amplifiers should be 5 m or less, and the wiring must be twisted.
(6) Specifications
Power regeneration common
converter FR-CV-_
Item
Total of connectable servo amplifier
capacities
Maximum servo amplifier capacity
Total of connectable servo
motor rated currents
Short-time rating
Regenerative
braking torque
Continuous rating
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply capacity
(Note 2)
IP rating (JEM 1030), cooling method
Ambient temperature
Ambient humidity
Ambience
Altitude, vibration resistance
Molded-case circuit breaker or earth-
leakage current breaker
Magnetic contactor
7.5K
11K
[kW]
3.75
5.5
[kW]
3.5
5
[A]
33
46
Total capacity of applicable servo motors, 300% torque, 60 s (Note 1)
3-phase 200 V AC to 220 V AC, 50 Hz, 200 V AC to 230 V AC, 60 Hz
3-phase 170 V AC to 242 V AC, 50 Hz, 170 V AC to 253 V AC, 60 Hz
[kVA]
17
20
Indoors (no direct sunlight), free from corrosive gas, flammable gas,
30AF
50AF
30A
50A
S-N20
S-N35
S-T21
S-T35
11 - 48
15K
22K
7.5
11
7
11
61
90
100% torque
±5%
28
41
Open type (IP00), forced cooling
-10 ˚C to 50 ˚C (non-freezing)
5 %RH to 90 %RH (non-condensing)
oil mist, dust, and dirt
1000 m or less above sea level, 5.9 m/s
100AF
100AF
75A
100A
S-N50
S-N65
S-T50
S-T65
30K
37K
55K
15
18.5
27.5
15
15
22
115
145
215
52
66
100
2
125AF
125AF
225AF
125A
125A
175A
S-N80
S-N95
S-N125
S-T80
S-T100