Mitsubishi Electric MR-J4-10B(-RJ) Instruction Manual page 33

General-purpose ac servo melservo-j4 sscnet /h interface mr-j4 series servo amplifier
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION
Model: MR-J4-_(-RJ)
Ambient
temperature
Ambient
humidity
Environment
Ambience
Altitude
Vibration resistance
Mass
Note 1. 0.3 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. Test pulse is a signal which instantaneously turns off a signal to the servo amplifier at a constant period for external circuit to
self-diagnose.
3. Except for the terminal block.
4. MR-J4-B4 servo amplifier is compatible only with two-wire type. MR-J4-B4-RJ servo amplifier is compatible with two-wire type,
four-wire type, and A/B/Z-phase differential output method. Refer to table 1.1 for details.
5. The communication cycle depends on the controller specifications and the number of axes connected.
6. Use an external dynamic brake for this servo amplifier. Failure to do so will cause an accident because the servo motor does
not stop immediately but coasts at emergency stop. Ensure the safety in the entire equipment.
7. For the compatible version for the scale measurement function, refer to table 1.1. Check the software version of the servo
amplifier with MR Configurator2.
8. The external dynamic brake cannot be used for compliance with SEMI-F47 standard. Do not assign DB (Dynamic brake
interlock) in [Pr. PD07] to [Pr. PD09]. Failure to do so will cause the servo amplifier to become servo-off when an
instantaneous power failure occurs.
9. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input
diagnosis by TOFB output is performed or not. For details, refer to the Function column of [Pr. PF18] in section 5.2.6.
10. Follow the restrictions in section 2.7 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level.
60B4
100B4
Operation
Storage
Operation
Storage
[kg]
1.7
200B4
350B4
500B4
0 ˚C to 55 ˚C (non-freezing)
-20 ˚C to 65 ˚C (non-freezing)
5 %RH to 90 %RH (non-condensing)
Indoors (no direct sunlight),
free from corrosive gas, flammable gas, oil mist, dust, and dirt
2000 m or less above sea level (Note 10)
5.9 m/s
2
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
2.1
3.6
4.3
1 - 16
700B4
11KB4
15KB4
6.5
13.4
22KB4
18.2

Hide quick links:

Advertisement

Table of Contents
loading