Power Supply Capacity And Generated Loss - Mitsubishi Electric MR-J4-10B(-RJ) Instruction Manual

General-purpose ac servo melservo-j4 sscnet /h interface mr-j4 series servo amplifier
Table of Contents

Advertisement

14. USING A LINEAR SERVO MOTOR

14.4.2 Power supply capacity and generated loss

Table 14.1 indicates servo amplifiers' power supply capacities and losses generated under rated load. For
thermal design of an enclosed type cabinet, use the values in the table in consideration for the worst
operating conditions. The actual amount of generated heat will be intermediate between values at rated
torque and servo-off according to the duty used during operation. When the linear servo motor is run at less
than the rated speed, the power supply capacity will be smaller than the value in the table, but the servo
amplifier's generated heat will not change.
Mounting a heat sink outside of the cabinet enables to reduce heat in the cabinet and design a compact
enclosed type cabinet.
Table 14.1 Power supply capacity and generated loss per linear servo motor at rated output
Linear servo motor
(primary side)
LM-H3P2A-07P-BSS0
LM-H3P3A-12P-CSS0
LM-H3P3B-24P-CSS0
LM-H3P3C-36P-CSS0
LM-H3P3D-48P-CSS0
LM-H3P7A-24P-ASS0
LM-H3P7B-48P-ASS0
LM-H3P7C-72P-ASS0
LM-H3P7D-96P-ASS0
LM-U2PAB-05M-0SS0
LM-U2PAD-10M-0SS0
LM-U2PAF-15M-0SS0
LM-U2PBB-07M-1SS0
LM-U2PBD-15M-1SS0
LM-U2PBF-22M-1SS0
LM-U2P2B-40M-2SS0
LM-U2P2C-60M-2SS0
LM-U2P2D-80M-2SS0
LM-FP2B-06M-1SS0
LM-FP2D-12M-1SS0
LM-FP2F-18M-1SS0
LM-FP4B-12M-1SS0
LM-FP4D-24M-1SS0
LM-FP4F-36M-1SS0
LM-FP4H-48M-1SS0
LM-FP5H-60M-1SS0
LM-K2P1A-01M-2SS1
LM-K2P1C-03M-2SS1
LM-K2P2A-02M-1SS1
LM-K2P2C-07M-1SS1
LM-K2P2E-12M-1SS1
LM-K2P3C-14M-1SS1
LM-K2P3E-24M-1SS1
Note 1. The power supply equipment capacity changes with the power supply impedance. This value is applicable when the power
factor improving AC reactor or power factor improving DC reactor is not used.
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by the
regenerative option, refer to section 11.2.
Power supply
Servo amplifier
capacity [kVA]
(Note 1)
MR-J4-40B(-RJ)
MR-J4-40B1(-RJ)
MR-J4-70B(-RJ)
MR-J4-200B(-RJ)
MR-J4-70B(-RJ)
MR-J4-200B(-RJ)
MR-J4-350B(-RJ)
MR-J4-20B(-RJ)
MR-J4-20B1(-RJ)
MR-J4-40B(-RJ)
MR-J4-40B1(-RJ)
MR-J4-20B(-RJ)
MR-J4-20B1(-RJ)
MR-J4-60B(-RJ)
MR-J4-70B(-RJ)
MR-J4-200B(-RJ)
MR-J4-350B(-RJ)
MR-J4-500B(-RJ)
MR-J4-200B(-RJ)
MR-J4-500B(-RJ)
MR-J4-700B(-RJ)
MR-J4-500B(-RJ)
MR-J4-700B(-RJ)
MR-J4-11KB(-RJ)
MR-J4-15KB(-RJ)
MR-J4-22KB4(-RJ)
MR-J4-40B(-RJ)
MR-J4-40B1(-RJ)
MR-J4-200B(-RJ)
MR-J4-70B(-RJ)
MR-J4-350B(-RJ)
MR-J4-500B(-RJ)
MR-J4-350B(-RJ)
MR-J4-500B(-RJ)
Servo amplifier-generated heat [W]
At rated output
0.9
35
0.9
35
1.3
50
1.9
75
3.5
90
1.3
50
3.5
90
3.8
100
5.5
130
0.5
25
0.9
35
0.9
35
0.5
25
1.0
40
1.3
50
3.5
90
5.5
130
7.5
195
3.5
90
7.5
195
10
300
7.5
195
10
300
14
460
18
580
22
640
0.9
35
3.5
90
1.3
50
5.5
130
7.5
195
5.5
130
7.5
195
14 - 31
Area required for
(Note 2)
heat dissipation
With servo-off
15
15
15
15
20
15
20
20
20
15
15
15
15
15
15
20
20
25
20
25
25
25
25
45
45
45
15
20
15
20
25
20
25
[m
]
2
0.7
0.7
1.0
1.5
1.8
1.0
1.8
1.1
2.7
0.5
0.7
0.7
0.5
0.8
1.0
1.8
2.7
3.9
1.8
3.9
6.0
3.9
6.0
9.2
11.6
12.8
0.7
1.8
1.0
2.7
3.9
2.7
3.9

Hide quick links: