3.6.3 Vertical axis freefall prevention function

The vertical axis freefall prevention function avoids machine damage by pulling up the shaft slightly like the
following case.
When the servo motor is used for operating vertical axis, the servo motor electromagnetic brake and the
base circuit shut-off delay time function avoid dropping axis at forced stop. However, the functions may not
avoid dropping axis a few μm due to the backlash of the servo motor electromagnetic brake.
The vertical axis freefall prevention function is enabled with the following conditions.
Other than "0" is set to [Pr. PC31 Vertical axis freefall prevention compensation amount].
EM2 (Forced stop 2) turned off, an alarm occurred, or SSCNET III/H communication shut-off occurred
while the servo motor speed is zero speed or less.
The base circuit shut-off delay time function is enabled.
(1) Timing chart
(2) Adjustment
Set the freefall prevention compensation amount in [Pr. PC31].
While the servo motor is stopped, turn off the EM2 (Forced stop 2). Adjust the base circuit shut-off
delay time in [Pr. PC02] in accordance with the travel distance ([Pr. PC31). Adjust it considering the
freefall prevention compensation amount by checking the servo motor speed, torque ripple, etc.

3.6.4 Residual risks of the forced stop function (EM2)

(1) The forced stop function is not available for alarms that activate the dynamic brake when the alarms
occur.
(2) When an alarm that activates the dynamic brake during forced stop deceleration occurs, the braking
distance until the servo motor stops will be longer than that of normal forced stop deceleration without
the dynamic brake.
(3) If STO is turned off during forced stop deceleration, [AL. 63 STO timing error] will occur.
ON
EM2 (Forced stop 2)
OFF (Enabled)
Position
Travel distance
Base circuit
ON
(Energy supply to
OFF
the servo motor)
MBR
ON
(Electromagnetic
OFF (Enabled)
brake interlock)
Actual operation of
Disabled
electromagnetic
brake
Enabled
Set the base circuit shut-off delay time. ([Pr. PC02])
3 - 32