Dimensions - Mitsubishi Electric MR-J4-10B(-RJ) Instruction Manual

General-purpose ac servo melservo-j4 sscnet /h interface mr-j4 series servo amplifier
Table of Contents

Advertisement

11. OPTIONS AND PERIPHERAL EQUIPMENT
Servo amplifier
MR-J4-500B4(-RJ)
400 V
class
MR-J4-700B4(-RJ)
MR-J4-11KB4(-RJ)
MR-J4-15KB4(-RJ)
MR-J4-22KB4(-RJ)
Note 1. Symbols in the applicable tool field indicate applicable tools in (4) (b) in this section.
2. Coat the crimping part with an insulation tube.
(b) Applicable tool

11.3.4 Dimensions

(1) FR-BU2-(H) brake unit
Brake unit
FR-BU2-H30K
FR-BU2-H30K
FR-BU2-H30K
FR-BU2-H55K
FR-BU2-H55K
FR-BU2-H55K
FR-BU2-H75K
Symbol
Crimp terminal
FDV5.5-S4
YNT-1210S
a
FDV5.5-6
b
8-4NS
YHT-8S
YF-1
c
FVD8-6
E-4
FVD14-6
YF-1
d
FVD14-8
E-4
FR-BU2-15K
φ5 hole
(Screw size: M4)
5
18.5
6
56
6
68
11 - 34
Number of
Crimp terminal (Manufacturer)
connected
units
1
FVD5.5-S4 (JST)
1
FVD5.5-S4 (JST)
1
FVD5.5-6 (JST)
1
FVD5.5-6 (JST)
1
FVD5.5-6 (JST)
1
FVD5.5-8 (JST)
1
FVD14-8 (JST)
Servo amplifier-side crimp terminals
Applicable tool
Body
Head
YNE-38
DH-111
DH-121
YNE-38
DH-112
DH-122
[Unit: mm]
Rating
plate
4
52
62
132.5
(Note 1)
Applicable
tool
a
a
a
a
a
a
d
Manufacturer
Dice
JST