Operation And Functions - Mitsubishi Electric MR-J4-10B(-RJ) Instruction Manual

General-purpose ac servo melservo-j4 sscnet /h interface mr-j4 series servo amplifier
Table of Contents

Advertisement

16. FULLY CLOSED LOOP SYSTEM

16.3 Operation and functions

16.3.1 Startup
(1) Startup procedure
Start up the fully closed loop system in the following procedure.
Selection of load-side encoder communication system (Refer to (3) in this section.)
Completion of installation and wiring
Adjustment and operation check in semi closed loop system
Positioning operation check using MR Configurator2
Adjustment and operation check in fully closed loop system
Selection of fully closed loop system (Refer to (2) in this section.)
Setting of load-side encoder polarity (Refer to (4) in this section.)
Setting of load-side encoder electronic gear (Refer to (5) in this section.)
Confirmation of load-side encoder position data (Refer to (6) in this section.)
Positioning operation check using MR Configurator2
Adjustment of dual feedback switching filter.
(for dual feedback control) (Refer to (5) in this section.)
Positioning operation check using the controller (Refer to section 16.3.3.)
Home position return operation (Refer to section 16.3.2.)
Positioning operation
Completion of fully closed loop system startup
Gain adjustment
Gain adjustment
16 - 9
Check that the servo
equipment is normal.
Do as necessary.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents