17. APPLICATION OF FUNCTIONS
No.
Symbol
PX13
*XOP2
Function selection X-2
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PX14
OTHOV
One-touch tuning - Overshoot permissible level
Set a permissible value of overshoot amount for one-touch tuning as a percentage of the in-
position range.
However, setting "0" will be 50%.
PX17
NH3
Machine resonance suppression filter 3
Set the notch frequency of the machine resonance suppression filter 3.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance suppression
filter 3 selection" in [Pr. PX18].
PX18
NHQ3
Notch shape selection 3
Set the shape of the machine resonance suppression filter 3.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PX19
NH4
Machine resonance suppression filter 4
Set the notch frequency of the machine resonance suppression filter 4.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance suppression
filter 4 selection" in [Pr. PX20].
Name and function
Explanation
One-touch tuning function selection
0: Disabled
1: Enabled
When the digit is "0", the one-touch tuning with MR Configurator2
will be disabled.
For manufacturer setting
Explanation
Machine resonance suppression filter 3 selection
0: Disabled
1: Enabled
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
Notch width selection
0: α = 2
1: α = 3
2: α = 4
3: α = 5
For manufacturer setting
17 - 20
Initial
Setting
value
range
[unit]
Refer to the
"Name and
Initial
function" column.
value
1h
0h
0h
0h
0
0
[%]
to
100
4500
10
[Hz]
to
4500
Refer to the
"Name and
function" column.
Initial
value
0h
0h
0h
0h
4500
10
[Hz]
to
4500

Hide quick links: