11. OPTIONS AND PERIPHERAL EQUIPMENT

11.3.3 Connection example

(1) Combination with FR-BR-(H) resistor unit
(a) When connecting a brake unit to a servo amplifier
1) 200 V class
MCCB
(Note 1)
Power
supply
(Note 10)
Main circuit
power supply
24 V DC (Note 12)
Note 1. For the power supply specifications, refer to section 1.3.
2. When using the servo amplifier of 7 kW or less, make sure to disconnect the wiring of built-in regenerative resistor (5 kW or
less: P+ and D, 7 kW: P+ and C). For the servo amplifier of 11 kW to 22 kW, do not connect a supplied regenerative resistor to
the P+ and C terminals.
3. Between P3 and P4 is connected by default. When using the power factor improving DC reactor, remove the short bar
between P3 and P4. Refer to section 11.11 for details. Additionally, a power factor improving DC reactor and power factor
improving AC reactor cannot be used simultaneously.
4. Connect P/+ and N/- terminals of the brake unit to a correct destination. Incorrect connection destination results in servo
amplifier and brake unit malfunction.
5. Contact rating: 1b contact, 110 V AC, 5 A/220 V AC, 3 A
Normal condition: TH1-TH2 is conducting. Abnormal condition: TH1-TH2 is not conducting.
6. Contact rating: 230 V AC, 0.3 A/30 V DC, 0.3 A
Normal condition: B-C is conducting./A-C is not conducting. Abnormal condition: B-C is not conducting./A-C is conducting.
7. Do not connect more than one cable to each P+ and N- terminals of the servo amplifier.
8. Always connect BUE and SD terminals. (factory-wired)
9. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop
deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn
off the magnetic contactor.
10. Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo
amplifier.
11. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker.
12. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
POINT
EM2 has the same function as EM1 in the torque control mode.
Connecting PR terminal of the brake unit to the P+ terminal of the servo
amplifier results in brake unit malfunction. Always connect the PR terminal of the
brake unit to the PR terminal of the resistor unit.
ALM
RA1
Emergency stop switch
Servo amplifier
(Note 9)
MC
L1
L2
L3
L11
L21
(Note 11)
CN3
EM2
20
5
DICOM
10
DICOM
OFF
ON
MC
CN3
24 V DC (Note 12)
3
DOCOM
15
ALM
P3
(Note 3)
P4
P+
(Note 7)
N-
C
(Note 2)
11 - 26
MC
SK
RA1
FR-BR
(Note 5)
P
PR
FR-BU2
PR
P/+
(Note 4)
N/-
BUE
(Note 8)
SD
TH1
TH2
MSG
SD
A
B
C
(Note 6)