ABB REL650 Technical Manual page 545

Hide thumbs Also See for REL650:
Table of Contents

Advertisement

1MRK 506 382-UEN A
Name
Values (Range)
PFDbRepInt
PFZeroDb
PFHiHiLim
PFHiLim
PFLowLim
PFLowLowLim
PFLimHyst
UDbRepInt
UZeroDb
UHiHiLim
UHiLim
ULowLim
ULowLowLim
ULimHyst
IDbRepInt
IZeroDb
IHiHiLim
IHiLim
ILowLim
ILowLowLim
ILimHyst
FrDbRepInt
FrZeroDb
FrHiHiLim
FrHiLim
FrLowLim
FrLowLowLim
FrLimHyst
UGenZeroDb
IGenZeroDb
UAmpComp5
Table continues on next page
Line distance protection REL650 2.2 IEC
Technical manual
Unit
1 - 100000
Type
0 - 100000
m%
-1.000 - 1.000
-
-1.000 - 1.000
-
-1.000 - 1.000
-
-1.000 - 1.000
-
0.000 - 100.000
%
1 - 100000
Type
0 - 100000
m%
0.0 - 200.0
%UB
0.0 - 200.0
%UB
0.0 - 200.0
%UB
0.0 - 200.0
%UB
0.000 - 100.000
%
1 - 100000
Type
0 - 100000
m%
0.0 - 500.0
%IB
0.0 - 500.0
%IB
0.0 - 500.0
%IB
0.0 - 500.0
%IB
0.000 - 100.000
%
1 - 100000
Type
0 - 100000
m%
0.000 - 100.000
Hz
0.000 - 100.000
Hz
0.000 - 100.000
Hz
0.000 - 100.000
Hz
0.000 - 100.000
%
1 - 100
%UB
1 - 100
%IB
-10.000 - 10.000
%
Step
Default
1
10
100
500
0.001
1.000
0.001
0.800
0.001
-0.800
0.001
-1.000
0.001
5.000
1
10
500
1000
0.1
150.0
0.1
120.0
0.1
80.0
0.1
60.0
0.001
5.000
1
10
500
1000
0.1
150.0
0.1
120.0
0.1
80.0
0.1
60.0
0.001
5.000
1
10
10
100
0.001
65.000
0.001
63.000
0.001
47.000
0.001
45.000
0.001
5.000
1
5
1
5
0.001
0.000
Section 14
Monitoring
Description
Cycl: Report interval (s), Db: In 0,001%
of range, Int Db: In 0,001%s
Magnitude zero point clamping in
0,001% of range
High High limit (physical value)
High limit (physical value)
Low limit (physical value)
Low Low limit (physical value)
Hysteresis value in % of range, common
for all limits
Cycl: Report interval (s), Db: In 0,001%
of range, Int Db: In 0,001%s
Magnitude zero point clamping in
0,001% of range
High High limit in % of UBase
High limit in % of UBase
Low limit in % of UBase
Low Low limit in % of UBase
Hysteresis value in % of range, common
for all limits
Cycl: Report interval (s), Db: In 0,001%
of range, Int Db: In 0,001%s
Magnitude zero point clamping in
0,001% of range
High High limit in % of IBase
High limit in % of IBase
Low limit in % of IBase
Low Low limit in % of IBase
Hysteresis value in % of range, common
for all limits
Cycl: Report interval (s), Db: In 0,001%
of range, Int Db: In 0,001%s
Magnitude zero point clamping in
0,001% of range
High High limit (physical value)
High limit (physical value)
Low limit (physical value)
Low Low limit (physical value)
Hysteresis value in % of range, common
for all limits
Zero point clamping in % of UBase
Zero point clamping in % of IBase
Amplitude factor to calibrate voltage at
5% of Ur