Call Waiting - AudioCodes Mediant 800B User Manual

Media gateway & enterprise session border controller (e-sbc)
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

SuppServCodeCFB - Call Forward on Busy
SuppServCodeCFBDeact - Call Forward on Busy Deactivation
SuppServCodeCFNR - Call Forward on No Reply
SuppServCodeCFNRDeact - Call Forward on No Reply Deactivation
Note:
These codes must be defined according to the settings of the softswitch (i.e.,
the softswitch must recognize them).
Below is an example of an INVITE message sent by the device indicating an unconditional
call forward ("*72") to extension number 100. This code is defined using the
SuppServCodeCFU parameter.
INVITE sip:*72100@10.33.8.53;user=phone SIP/2.0
Via: SIP/2.0/UDP 10.33.2.5:5060;branch=z9hG4bKWDSUKUHWFEXQSVOUVJGM
From: <sip:400@10.33.2.5;user=phone>;tag=DUOROSXSOYJJLNBFRQTG
To: <sip:*72100@10.33.8.53;user=phone>
Call-ID: GMNOVQRRXUUCYCQSFAHS@10.33.2.5
CSeq: 1 INVITE
Contact: <sip:400@10.33.2.5:5060>
Supported: em,100rel,timer,replaces
Allow:
REGISTER,OPTIONS,INVITE,ACK,CANCEL,BYE,NOTIFY,PRACK,REFER,INFO,SUB
SCRIBE
User-Agent: Sip Message Generator V1.0.0.5
User-to-User: 31323334;pd=4
Content-Type: application/sdp
Content-Length: 155
26.7

Call Waiting

The Call Waiting feature enables FXS devices to accept an additional (second) call on
busy endpoints. If an incoming IP call is designated to a busy port, the called party hears a
call waiting tone (several configurable short beeps) and (for Bellcore and ETSI Caller IDs)
can view the Caller ID string of the incoming call. The calling party hears a call waiting
ringback tone. The called party can accept the new call using hook-flash, and can toggle
between the two calls.
To enable call waiting:
1.
Set the parameter EnableCallWaiting to 1.
2.
Set the parameter EnableHold to 1.
3.
Define the Call Waiting indication and call waiting ringback tones in the Call Progress
Tones file. You can define up to four call waiting indication tones (refer to the
FirstCallWaitingToneID parameter).
4.
To configure the call waiting indication tone cadence, modify the following parameters:
NumberOfWaitingIndications,
TimeBetweenWaitingIndications.
5.
To configure a delay interval before a Call Waiting Indication is played to the currently
busy port, use the parameter TimeBeforeWaitingIndication. This enables the caller to
hang up before disturbing the called party with Call Waiting Indications. Applicable
only to FXS modules.
Both the calling and called sides are supported by FXS interfaces; FXO interfaces support
only the calling side.
User's Manual