staging warehouse. The URL is configured using the IniFileURL parameter.
Private labeling (preconfigured during the manufacturing process).
Using DHCP Option 67 (see Provisioning from HTTP Server using DHCP Option 67
on page 778).
Manually on-site, using the RS-232 port or Web interface.
When the device is deployed at the customer site, local DHCP server provides the devices
with IP addressing and DNS server information. From the URL provided in the DHCP
response, the device can then contact the HTTP server at the core network and
automatically download its configuration. The URL can be a simple file name or contain the
device's MAC or IP address, e.g.:
http://corp.com/config-<MAC>.ini - which becomes, for example,
http://corp.com/config-00908f030012.ini
http://corp.com/<IP>/config.ini - which becomes, for example,
http://corp.com/192.168.0.7/config.ini
For more information on HTTP-based provisioning, see ''HTTP/S-Based Provisioning using
the Automatic Update Feature'' on page 781.

45.1.3 FTP- based Provisioning

Some networks block access to HTTP(S). The Automatic Update feature provides limited
support for FTP/FTPS connectivity. Periodic polling for updates is not possible since these
protocols do not support conditional fetching, i.e., updating files only if it is changed on the
server.
The only difference between this method and those described in ''HTTP-based
Provisioning'' on page
page 778 is that the protocol in the URL is "ftp" (instead of "http").

45.1.4 Provisioning using AudioCodes EMS

AudioCodes EMS server functions as a core-network provisioning server. The device's
SNMP Manager should be configured with the IP address of the EMS server, using one of
the methods detailed in the previous sections. As soon as a registered device contacts the
EMS server through SNMP, the EMS server handles all required configuration
automatically, upgrading software as needed. This alternative method doesn't require
additional servers at the customer premises, and is NAT-safe.
User's Manual
779
and Provisioning from HTTP Server using DHCP Option 67 on
780
Mediant 800B Gateway and E- SBC