Only one RADIUS server is configured and used for authorization and accounting
purposes (no redundancy). Therefore, both the Authorization and Accounting ports are
defined.
Three RADIUS servers are configured:
Two servers are used for authorization purposes only, providing redundancy.
Therefore, only the Authorization ports are defined, while the Accounting ports
are set to 0.
One server is used for accounting purposes only (i.e., no redundancy). Therefore,
only the Accounting port is defined, while the Authorization port is set to 0.
Two RADIUS servers are configured and used for authorization and accounting
purposes, providing redundancy. Therefore, both the Authorization and Accounting
ports are defined.
The status of the RADIUS severs can be viewed using the following CLI command:
# show system radius servers status
The example below shows the status of two RADIUS servers in redundancy mode for
authorization and accounting:
servers 0
ip-address 10.4.4.203
auth-port 1812
auth-ha-state "ACTIVE"
acc-port 1813
acc-ha-state "ACTIVE"
servers 1
ip-address 10.4.4.202
auth-port 1812
auth-ha-state "STANDBY"
acc-port 1813
acc-ha-state "STANDBY"
Where auth-ha-state and acc-ha-state display the authentication and accounting
redundancy status respectively. "ACTIVE" means that the server was used for the last sent
authentication or accounting request; "STANDBY" means that the server was not used in
the last sent request.
The following procedure describes how to configure a RADIUS server through the Web
interface. You can also configure it through ini file (RadiusServers) or CLI configure system
> radius > servers).
Note:
To enable and configure RADIUS-based accounting, see ''Configuring RADIUS
Accounting'' on page 852.
To configure a RADIUS server:
1.
Open the RADIUS Servers table (Configuration tab > System menu > Management
> RADIUS Servers).