Ha Configuration; Initial Ha Configuration; Network Topology Types And Rx/Tx Ethernet Port Group Settings - AudioCodes Mediant 800B User Manual

Media gateway & enterprise session border controller (e-sbc)
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

User's Manual
39

HA Configuration

This section describes the configuration of the HA system.
39.1

Initial HA Configuration

By default, HA is disabled on the device. When a device is loaded with valid HA
configuration and it is the first device to be loaded, it becomes the active device. The
second device that is loaded with HA configuration becomes the redundant (standby)
device.
39.1.1 Network Topology Types and Rx/Tx Ethernet Port Group
Settings
The initial configuration of HA depends on how you want to deploy your HA system in the
network. The Maintenance interface, used for the HA link between Active and Redundant
units, must be configured on a dedicated Ethernet Device and Ethernet Group (port),
separate from the other IP network interfaces. The separation of the Maintenance interface
from other interfaces must also be done externally to the units, either by physical
separation (i.e., different physical networks) or by logical separation (using VLANs). When
using VLANs for this separation, make sure that you use a different Underlying Ethernet
Device for each IP network interface (see Configuring Underlying Ethernet Devices on
page 132 and Configuring IP Network Interfaces on page 135).
Note:
interfaces, logical separation of traffic may not occur.
The Maintenance interface can employ Ethernet port redundancy (recommended), by
using two ports. This is enabled by configuring the Ethernet Group associated with the
Maintenance interface with two ports. The required receive (Rx) and transmit (TX) mode for
the port pair in the Ethernet Group used by the Maintenance interface is as follows:
(Recommended Physical Connectivity) If the Maintenance ports of both devices are
connected directly to each other without intermediation of switches, configure the
mode to 2RX/1TX:
Version 7.0
If you assign the same Underlying Ethernet Device to all the IP network
Figure 39-1: Rx/Tx Mode for Direct Connection
715
Mediant 800B Gateway and E- SBC
39. HA Configuration

Advertisement

Table of Contents
loading

Table of Contents