61.3.4 Resource Allocation Indication Parameters

The Resource Allocation Indication (RAI) parameters are described in the table below.
Parameter
[EnableRAI]
[RAIHighThreshold]
[RAILowThreshold]
[RAILoopTime]

61.3.5 HA Ping Parameters

The High Availability (HA) Ping parameters are described in the table below.
Parameter
HA Device Name
configure system >
high-availability >
unit-id-name
[HAUnitIdName]
HA Remote Address
configure system >
high-availability >
remote-address
Version 7.0
Table 61-21: RAI Parameters
Enables Resource Available Indication (RAI) alarm generation if the
device's busy endpoints exceed a user-defined threshold, configured by
the RAIHighThreshold parameter. When enabled and the threshold is
crossed, the device sends the SNMP trap, acBoardCallResourcesAlarm.
[0] = (Default) Disable
[1] = Enable
Note: For the parameter to take effect, a device reset is required.
Defines the high threshold percentage of total calls that are active (busy
endpoints). When the percentage of the device's busy endpoints
exceeds this high threshold, the device sends the SNMP
acBoardCallResourcesAlarm alarm trap with a 'major' alarm status.
The range is 0 to 100. The default is 90.
Note: The percentage of busy endpoints is calculated by dividing the
number of busy endpoints by the total number of "enabled" endpoints
(trunks are physically connected and synchronized with no alarms and
endpoints are defined in the Trunk Group table).
Defines the low threshold percentage of total calls that are active (busy
endpoints).
When the percentage of the device's busy endpoints falls below this low
threshold, the device sends an SNMP acBoardCallResourcesAlarm
alarm trap with a 'cleared' alarm status.
The range is 0 to 100%. The default is 90%.
Defines the time interval (in seconds) that the device periodically checks
call resource availability.
The valid range is 1 to 200. The default is 10.
Table 61-22: HA Ping Parameters
Defines a name for the device, which is displayed on the Home page to
indicate the active device.
The valid value is a string of up to 128 characters. The default value is
"Device 1" for the active device and "Device 2" for the redundant device.
Defines the Maintenance interface address of the redundant device in
the HA system.
By default, no value is defined.