User's Manual
57
Analog Line Testing
57.1
FXO Line Testing
The device can test the telephone lines connected to its FXO ports, using the SNMP
acAnalogFxoLineTestTable table. These tests provide various line measurements. In
addition to these tests, a keep-alive test is also done every 100 msec on each of the
analog ports to detect communication problems with the analog equipment:
Line Current (mA)
Line Voltage (V)
Hook (0 = on-hook; 1 = off-hook)
Ring (0 - Off; 1 - On)
Line Connected (0 = Disconnected; 1 = Connected)
Polarity state (0 = Normal; 1 = Reversed, 2 = N\A)
Line polarity (0 = Positive; 1 = Negative)
Message Waiting Indication (0 = Off; 1 = On)
Note:
there are calls in progress.
Version 7.0
Use the Analog Line testing mechanism only for monitoring and never when
885
Mediant 800B Gateway and E- SBC
57. Analog Line Testing